PIM00424
11-3
11.4
Monitor mode
11.4.1
Monitor mode display item list
In monitor mode, you can monitor the items in the table below by panel operation.
Monitor
number
Name Unit
Remarks
MPa
n00
Pressure switch setting
×10PSI
Displays the pressure switch setting.
MPa
n01 Pressure
setting
×10PSI
Displays the pressure settings of the current P-Q selection
number.
n02
Flow rate setting
L/min
Displays the flow rate settings of the current P-Q selection
number.
n03
Flow rate
L/min
Displays the current flow rate.
n04
Latest alarm code
−
Displays the latest alarm code.
Press the
key, you can check the number of power-on
times.
n05 rpm
×10min
-1
Displays the current rpm.
n06 Operating
status
−
Displays the PQ selection number. "L" is a fixed sign.
(Example)
low pressure (confluence) PQ selection
No.1
n07
Reverse rpm at power-
OFF
min
-1
Displays a motor reverse rpm due to counter-flow from the load
when the unit power supply is turned OFF. This parameter is
used to estimate the machine load volume.
n08
Regenerative load
integration ratio
%
Displays the load integration ratio of the current regenerative
braking resistance.
n09
(Reserved for system)
―
Reserved
for
system
n10
Motor thermistor
temperature
℃
Displays the temperature detected by the thermistor in the
motor.
n11
Fin thermistor
temperature
℃
Displays the temperature detected by the thermistor in the fin.
n12
Main circuit DC voltage
V
Displays the controller’s internal DC voltage. The voltage value
is indicated as power supply voltage multiplied by
√
2. The
voltage value may change depending on its operating
conditions.
n
13
Analog input voltage 1
V
Displays the input voltage of the analog input terminal AIN1.
n14
Analog input voltage 2
V
Displays the input voltage of the analog input terminal AIN2.
n15
Analog output voltage 1
V
Displays the output voltage of the analog output terminal AO1.
n16
Analog output voltage 2
V
Displays the output voltage of the analog output terminal AO2.
n17
(Reserved for system)
―
Reserved
for
system
n18
(Reserved for system)
―
Reserved
for
system
n19
(Reserved for system)
―
Reserved
for
system
n20
(Reserved for system)
―
Reserved
for
system
n21
(Reserved for system)
―
Reserved
for
system
n22
(Reserved for system)
―
Reserved
for
system
n23
(Reserved for system)
―
Reserved
for
system
Summary of Contents for Super Unit SUT00D8021-30
Page 2: ......
Page 12: ......
Page 19: ...PIM00424 3 5 3 4 Dimensions Motor Pump Type SUT00 SUT00S8007 30 ...
Page 20: ...PIM00424 3 6 SUT00D8021 30 ...
Page 21: ...PIM00424 3 7 Unit Type SUT10 SUT16 SUT10S8007 30 ...
Page 22: ...PIM00424 3 8 SUT10D8021 30 ...
Page 23: ...PIM00424 3 9 SUT16D8021 30 ...
Page 28: ......
Page 32: ......
Page 34: ......
Page 38: ......
Page 42: ......
Page 50: ......
Page 60: ......
Page 92: ......