4002 SERIES 

ULTRASONIC GENERATOR 

 
 

OPERATOR'S MANUAL 

 
 
 
 
 

L&R Manufacturing Company

 

577 Elm Street 

Kearny, NJ  07032-3604 USA 

 

 

 

   CN 80406   Rev. E         

 

 
 

Summary of Contents for 4002 Series

Page 1: ...4002 SERIES ULTRASONIC GENERATOR OPERATOR S MANUAL L R Manufacturing Company 577 Elm Street Kearny NJ 07032 3604 USA CN 80406 Rev E ...

Page 2: ...TIONS 3 0 SPECIFICATIONS 4 0 INSTALLATION PROCEDURE 5 0 DIGITAL TIMER OPERATING INSTRUCTIONS 6 0 SYSTEM CONTROL 7 0 REPLACEMENT PARTS LIST WARNING If the equipment is used in a manner not specified by the manufacturer the protection provided by the equipment may be impaired ...

Page 3: ...ound Do not operate or apply power to a system until ALL Protective Earth PE grounds have been connected WARNING Avoid use of flammable solutions such as gasoline benzene benzol etc in cleaning tank WARNING Disconnect all Mains Power prior to any service WARNING Insure proper system grounding Keep area and equipment dry and clean WARNING Do not open generator while unit is plugged in Dangerous hig...

Page 4: ...17695 17696 117 230 3 3 1500 W 1500 W T30 0A 250V T15 0A 250V 12 9A 110V 6 9A 230V 4002 1 3 17683 17684 117 230 1 1 300 W 300 W T10 0A 250V T5 0A 250V 2 7A 110V 1 36A 230V 4002 1 4 17681 17682 117 230 1 1 400 W 400 W T10 0A 250V T5 0A 250V 3 6A 110V 1 8A 230V 4002ST 1 6 18245 18246 117 230 1 1 600 W 600 W T10 0A 250V T5 0A 250V 5 1A 117V 2 7A 230V 4002ST 2 6 18261 18262 117 230 2 2 1200 W 1200 W T...

Page 5: ...m of 3 inches above top of transducer for non heated system and no less than 3 inches from the top for a heated tank Note that solution displacement when submerging part to be cleaned must be taken into account Prevent the solution level from getting lower than the minimum to prevent heater failure or transducer failure Turn heater and ultrasonic power off before draining tank Plug generator s AC ...

Page 6: ...n timer When you set the value press the button START RESUME When the value reaches 0 the relay is turned OFF and the beeper beeps 6 sets of 2 250ms beeps Repeat Feature the timer will remember the last time set If you desire to change the setting from the original setting press start switch to recall previous setting then input new setting To enter one of the 3 countdown modes press and hold the ...

Page 7: ...rom 41 Khz to 45 Khz and then back to 41 Khz all in one second this would be a sweep rate of 1 if the sweep rate was set to a maximum the generators would sweep their frequency from 41 Khz to 45 Khz and then back to 41 Khz one hundred times a second this would be a sweep rate of 100 Power Control Optional Each generator has a power control function knob This adjustment serves to select an operatio...

Page 8: ...8 7 0 REPLACEMENT PARTS LIST DESCRIPTION C N FUSE HOLDER 30129 FUSE 5 AMP 31591 FUSE 10 AMP 30126 FUSE 15 AMP 32291 FUSE 20 AMP 30128 FUSE 30 AMP 31913 ...

Page 9: ...year from the date of purchase to be free of defects in material and workmanship Machine will be repaired free of charge to the customer during the warranty period This warranty does not include damage or product failure resulting from misuse abuse or transportation damage Operating the machine dry is the most common misuse which results in failure ...

Page 10: ...VISION HISTORY C N 80406 REVISION ECN DESCRIPTION APPROVED DATE C 8294 SEE ECN J P M 01 22 2007 D 8316 REVISED SHEET 4 SEE ECN 8316 J P M 01 24 2007 E 8725 REVISED SHEET 5 2000 M was 2000 Ft J P M 11 17 2010 ...