    SPECIFICATIONS

 

 

 

 
 

 

 

SYSTEM CONTROL:

  Individual section ON/OFF power switch. "Ultrasonics On" indicator                  

   

 

 

     light. 99 minute digital timer with L.E.D. standard display. Optional 99 

   

 

 

     Hour Timer Control. Optional Remote Control. Sweep rate adjustment, 

   

 

 

     ST version, power control (optional). Wattmeter (optional). 

 

 ULTRASONIC FREQUENCY:

  43 KHz. Opt. Sweep Range: +/- 2Khz, Sweep Rate: 1—100 Hz 

 

Generator Overall Dimensions:

 



Last digit in model number may be 6, 5, 4, 3 or a suffix of ST. 

MODEL 

NUMBER

 

PRODUC

CODE

 

Voltag

BOARD 

SECTIONS

 

TOTAL 

POWER  

Main FUSE Data 

CURRENT 

REQUIREMENTS 

4002-1/6 

17677 
17678 

117 
230 


600 W 
600 W 

T10.0A/250V 

T5.0A/250V 

5.1A 110V 
2.7A 230V 

4002-2/6 

17685 
17686 

117 
230 


1200 W 
1200 W 

T20.0A/250V 
T10.0A/250V 

10.2A 110V 

5.4A 230V 

4002-3/6 

17693 
17694 

117 
230 


1800 W 
1800 W 

T30.0A/250V 
T15.0A/250V 

15.3A 110V 

8.1A 230V 

4002-1/5 

17679 
17680 

117 
230 


500 W 
500 W 

T10.0A/250V 

T5.0A/250V 

4.3A 110V 
2.3A 230V 

4002-2/5 

17687 
17688 

117 
230 


1000 W 
1000 W 

T20.0A/250V 
T10.0A/250V 

8.6A 110V 
4.6A 230V 

4002-3/5 

17695 
17696 

117 
230 


1500 W 
1500 W 

T30.0A/250V 
T15.0A/250V 

12.9A 110V 

6.9A 230V 

4002-1/3 

17683 
17684 

117 
230 


300 W 
300 W 

T10.0A/250V 

T5.0A/250V 

2.7A 110V 

1.36A 230V 

4002-1/4 

17681 
17682 

117 
230 


400 W 
400 W 

T10.0A/250V 

T5.0A/250V 

3.6A 110V 
1.8A 230V 

4002ST-1/6 

18245 
18246 

117 
230 


600 W 
600 W 

T10.0A/250V 

T5.0A/250V 

5.1A 117V 
2.7A 230V 

4002ST-2/6 

18261 
18262 

117 
230 


1200 W 
1200 W 

T20.0A/250V 
T10.0A/250V 

10.2A 117V 

5.4A 230V 

4002ST-3/6 

18277 
18278 

117 
230 


1800 W 
1800 W 

T30.0A/250V 
T15.0A/250V 

15.3A 117V 

8.1A 230V 

4002ST-1/5 

18241 
18242 

117 
230 


500 W 
500 W 

T10.0A/250V 

T5.0A/250V 

4.3A 117V 
2.3A 230V 

4002ST-2/5 

18257 
18258 

117 
230 


1000 W 
1000 W 

T20.0A/250V 
T10.0A/250V 

8.6A 117V 
4.6A 230V 

4002ST-1/3 

18233 
18234 

117 
230 


300 W 
300 W 

T10.0A/250V 

T5.0A/250V 

2.7A 117V 
1.4A 230V 

Note: Board section fuse is T10.0A/250V for 117 volt units and T5.0A/250V for 230 volt units  
** Generator line frequency is 50/60 Hz 

  *** Do Not position equipment so that it is difficult to operate the disconnecting device. 
  **** Disconnect unit from mains by unplugging the line cord. 

 

4002-1/6 

9.2”Wx8”Hx17.7D 

18Lbs 

4002-2/6 

14”Wx8”Hx17.7”D 

28Lbs 

4002-3/6 

22”Wx8”Hx17.7”D 

38Lbs 

Model Number *  

Overall Size 

Weight 

Summary of Contents for 4002 Series

Page 1: ...4002 SERIES ULTRASONIC GENERATOR OPERATOR S MANUAL L R Manufacturing Company 577 Elm Street Kearny NJ 07032 3604 USA CN 80406 Rev E ...

Page 2: ...TIONS 3 0 SPECIFICATIONS 4 0 INSTALLATION PROCEDURE 5 0 DIGITAL TIMER OPERATING INSTRUCTIONS 6 0 SYSTEM CONTROL 7 0 REPLACEMENT PARTS LIST WARNING If the equipment is used in a manner not specified by the manufacturer the protection provided by the equipment may be impaired ...

Page 3: ...ound Do not operate or apply power to a system until ALL Protective Earth PE grounds have been connected WARNING Avoid use of flammable solutions such as gasoline benzene benzol etc in cleaning tank WARNING Disconnect all Mains Power prior to any service WARNING Insure proper system grounding Keep area and equipment dry and clean WARNING Do not open generator while unit is plugged in Dangerous hig...

Page 4: ...17695 17696 117 230 3 3 1500 W 1500 W T30 0A 250V T15 0A 250V 12 9A 110V 6 9A 230V 4002 1 3 17683 17684 117 230 1 1 300 W 300 W T10 0A 250V T5 0A 250V 2 7A 110V 1 36A 230V 4002 1 4 17681 17682 117 230 1 1 400 W 400 W T10 0A 250V T5 0A 250V 3 6A 110V 1 8A 230V 4002ST 1 6 18245 18246 117 230 1 1 600 W 600 W T10 0A 250V T5 0A 250V 5 1A 117V 2 7A 230V 4002ST 2 6 18261 18262 117 230 2 2 1200 W 1200 W T...

Page 5: ...m of 3 inches above top of transducer for non heated system and no less than 3 inches from the top for a heated tank Note that solution displacement when submerging part to be cleaned must be taken into account Prevent the solution level from getting lower than the minimum to prevent heater failure or transducer failure Turn heater and ultrasonic power off before draining tank Plug generator s AC ...

Page 6: ...n timer When you set the value press the button START RESUME When the value reaches 0 the relay is turned OFF and the beeper beeps 6 sets of 2 250ms beeps Repeat Feature the timer will remember the last time set If you desire to change the setting from the original setting press start switch to recall previous setting then input new setting To enter one of the 3 countdown modes press and hold the ...

Page 7: ...rom 41 Khz to 45 Khz and then back to 41 Khz all in one second this would be a sweep rate of 1 if the sweep rate was set to a maximum the generators would sweep their frequency from 41 Khz to 45 Khz and then back to 41 Khz one hundred times a second this would be a sweep rate of 100 Power Control Optional Each generator has a power control function knob This adjustment serves to select an operatio...

Page 8: ...8 7 0 REPLACEMENT PARTS LIST DESCRIPTION C N FUSE HOLDER 30129 FUSE 5 AMP 31591 FUSE 10 AMP 30126 FUSE 15 AMP 32291 FUSE 20 AMP 30128 FUSE 30 AMP 31913 ...

Page 9: ...year from the date of purchase to be free of defects in material and workmanship Machine will be repaired free of charge to the customer during the warranty period This warranty does not include damage or product failure resulting from misuse abuse or transportation damage Operating the machine dry is the most common misuse which results in failure ...

Page 10: ...VISION HISTORY C N 80406 REVISION ECN DESCRIPTION APPROVED DATE C 8294 SEE ECN J P M 01 22 2007 D 8316 REVISED SHEET 4 SEE ECN 8316 J P M 01 24 2007 E 8725 REVISED SHEET 5 2000 M was 2000 Ft J P M 11 17 2010 ...

Reviews: