12.4
Output signal Setting
The digital output, and the signal type can be selected by parameters, as shown in the table below.
12.4.1
Parameter
■
Parameters for output signal
Display Sign
Parameter
Name
Range
Factory Default
Setting
Unit
P07 WN_M Warning
output
level
0
〜
2
0 -
P08 AMIX
Alarm
output
mix
0
〜
2
1 -
P39 DO_S Digital
output
selection 0
〜
7
0 -
12.4.2
[P39: DO_S] Digital output selection
By changing the parameter "P39: Digital output selection ", the function of digital output DO1 can be selected.
■
Digital output DO1 selection
P39: Digital output selection
Function
Description
0
PQ number switching
completion output
When switch the PQ selection number, if the pressure
command, flow rate command reach the goal, it will
become ON.
1
Motor running output
It will become ON when the motor power is on.
2
High-pressure side
running output
It will become ON, if only the high pressure side runs.
3
(Reserved for system)
(Reserved for system)
4
Pressure and flow
coincidence output
It will become ON, when the flow rate or pressure
match.
5
Pressure coincidence
output
It will become ON , when the pressure matches.
6
Flow rate coincidence
output
It will become ON , when the flow rate matches.
7
Fully charged Output
It will become ON, if the main circuit is charged fully.
■
Pressure coincidence / Flow rate coincidence detection
The current pressure and flow rate can be detected, when the pressure or flow rate command value is within a
certain range.
The coincidence detection range, by setting a percentage of the command value, is limited by the coincidence
detection minimum.
No. Sign
Name
Range
Factory Default
Setting
Unit
P41 PCMW
Pressure coincidence
detection range
0
〜
99
5 %
P42 PCMM
The minimum value of
pressure coincidence
detection
0.0
〜
99.9
0.1 MPa
P43 QCMW
Flow rate coincidence
detection range
0
〜
99
5 %
P44 QCMM
The minimum value of
flow rate coincidence
detection
0.0
〜
99.9
0.2 L/min
Summary of Contents for Super Unit SUT00D8021-30
Page 2: ......
Page 12: ......
Page 19: ...PIM00424 3 5 3 4 Dimensions Motor Pump Type SUT00 SUT00S8007 30 ...
Page 20: ...PIM00424 3 6 SUT00D8021 30 ...
Page 21: ...PIM00424 3 7 Unit Type SUT10 SUT16 SUT10S8007 30 ...
Page 22: ...PIM00424 3 8 SUT10D8021 30 ...
Page 23: ...PIM00424 3 9 SUT16D8021 30 ...
Page 28: ......
Page 32: ......
Page 34: ......
Page 38: ......
Page 42: ......
Page 50: ......
Page 60: ......
Page 92: ......