Outdoor Unit - 50 Class
SiBE041012_A
211
Removal Procedure
4
Remove the sound
blanket (top lower).
5
Remove the sound
blanket (inner).
6
Release the discharge
pipe thermistor.
Be careful not to lose the clip
for the thermistor.
7
Cut the clamp and pull
out the
outdoor heat
exchanger thermistor.
Step
Procedure
Points
Sound blanket
(top lower)
(R11398)
Sound blanket
(inner)
(R5296)
(R12286)
Discharge pipe thermistor
(R12287)
Clip
(R5292)
Clamp
Outdoor heat
exchanger
thermistor