Inverter Single Split
4
Caution
Installation of a leakage breaker is necessary in some cases depending on the conditions
of the installation site, to prevent electrical shocks.
Do not install the equipment in a place where there is a possibility of combustible gas
leaks.
If a combustible gas leaks and remains around the unit, it can cause a
fi
re.
Be sure to install the packing and seal on the installation frame properly.
If the packing and seal are not installed properly, water can enter the room and wet the
furniture and
fl
oor.
For integral
units only
Inspection after Repair
Warning
Check to make sure that the power cable plug is not dirty or loose, then insert the plug into
a power outlet all the way.
If the plug has dust or loose connection, it can cause an electrical shock or
fi
re.
If the power cable and lead wires have scratches or deteriorated, be sure to replace them.
Damaged cable and wires can cause an electrical shock,excessive heat generation or
fi
re.
Do not use a joined power cable or extension cable, or share the same power outlet
with other electrical appliances, since it can cause an electrical shock, excessive heat
generation or
fi
re.
Caution
Check to see if the parts and wires are mounted and connected properly, and if the
connections at the soldered or crimped terminals are secure.
Improper installation and connections can cause excessive heat generation,
fi
re or an
electrical shock.
If the installation platform or frame has corroded, replace it.
Corroded installation platform or frame can cause the unit to fall, resulting in injury.
Check the grounding, and repair it if the equipment is not properly grounded. Improper
grounding can cause an electrical shock.
Be sure to measure the insulation resistance after the repair, and make sure that the
resistance is 1 Mohm or higher.
Faulty insulation can cause an electrical shock.
Be sure to check the drainage of the indoor unit after the repair.
Faulty drainage can cause the water to enter the room and wet the furniture and
fl
oor.
Summary of Contents for SKYAIR
Page 1: ...R410A SERVICE MANUAL SKYAIR Inverter Single Split SM 5CKY CCY CEY EU A1...
Page 3: ...ii...
Page 29: ...Wiring Diagram 26 Wiring Diagram Model ABQ71 100 125 140AV1 Model ACQ71 100 125AV1...
Page 30: ...Wiring Diagram 27 Model AHQ71AV1 Model AHQ100 125AV1...
Page 31: ...Wiring Diagram 28 Model AHQ140AV1 Model ABQ140BV1...
Page 32: ...Wiring Diagram 29 Model ACQ100 125BV1 Model ABQ71 100CV1...
Page 33: ...Wiring Diagram 30 Model ABQ125 140CV1 Model ACQ71 100 125CV1...
Page 34: ...Wiring Diagram 31 Model AHQ71 100 125CV1 Model AHQ140CV1...