background image

English

Never touch the internal parts of the control-

 

ler. Do not remove the front panel because 
some parts inside are dangerous to touch. To 
check and adjust internal parts, contact your 
dealer.

 CAUTION

Do not use the air conditioner for any other 

• 

purposes other than comfort cooling or heat-
ing. Do not use the unit for cooling precision 
instruments, food, plants, animals or works 
of art.

Do not place items under the indoor unit as 

• 

they may be damaged by condensates that 
may form if the humidity is above 80% or if 
the drain outlet gets blocked.

Before cleaning, stop the operation of the 

• 

unit by turning the power off or by pulling the 
supply cord out from its receptacle. Other-
wise, an electric shock and injury may result.

Do not wash the air conditioner with exces-

• 

sive water. An electric shock or fi re may re-
sult.

Avoid placing the controller in a spot 

• 

splashed with water. Water entering the con-
troller may cause an electric shock or dam-
age the internal electronic parts.

Do not operate the air conditioner when us-

• 

ing a room-fumigation type of insecticide. 
Failure to observe this could cause the 
chemicals to be deposited in the unit and can 
endanger the health of those who are hyper-
sensitive to chemicals.

Do not turn off the power immediately after 

• 

stopping operation. Always wait for at least 
fi ve minutes before turning off the power. 
Otherwise, water leakage may occur.

The appliance is not intended for use by 

• 

young children or infi rm persons without 
supervision.

The remote controller should be kept away 

• 

from children so they cannot play with it.

Consult with the installation contractor for 

• 

cleaning.

Incorrect cleaning of the inside of the air con-

• 

ditioner could make the plastics parts break 
and cause water leakage or electric shock.

Do not touch the air inlet or aluminum fi n of 

• 

the air conditioner as they can cut and cause 
injury.

Do not place objects in direct proximity of 

 

the outside unit. Do not let leaves and other 
debris accumulate around the unit. Leaves 
are a hotbed for small animals which can 
enter the unit. Once inside the unit, animals 
can cause the unit to malfunction, and cause 
smoke or fi re when they make contact with 
electrical parts.

 NOTE

Never press the button of the remote control-

• 

ler with a hard, pointed object. The remote 
controller may be damaged.

Never pull or twist the electric wire of the 

• 

remote controller. It may cause the unit to 
malfunction.

Do not place appliances that produce open 

• 

fl ames in places that are exposed to the air 
fl ow of the unit or under the indoor unit. It 
may cause incomplete combustion or defor-
mation of the unit due to the heat.

Do not expose the controller to direct sun-

• 

light. The LCD display can become discol-
ored and may fail to display the data.

Dismantling of the unit, disposal of the refrig-

• 

erant, oil, and additional parts, should be 
done in accordance with the relevant local, 
state, and national regulations.

Operate the air conditioner in a suffi ciently 

• 

ventilated area and not surrounded by ob-
stacles. Do not use the air conditioner in the 
following places.
 a. Places with a mist of mineral oil, such as 

cutting oil.

 b. Locations such as coastal areas where 

there is a lot of salt in the air.

 c. Locations such as hot springs where there 

is a lot of sulfur in the air.

 d. Locations such as factories where the pow-

er voltage varies a lot.

 e. In cars, boats, and other vehicles.
 f. Locations such as kitchens where oil may 

splatter or where there is steam in the air.

 g. Locations where equipment produces elec-

tromagnetic waves.

 h. Places with an acid or alkaline mist.
 i. Places where fallen leaves can accumulate 

or where weeds can grow.

01_EN_3P250362-3A.indd   3

01_EN_3P250362-3A.indd   3

3/16/2010   4:24:03 PM

3/16/2010   4:24:03 PM

Summary of Contents for SkyAir FTQ18PAVJU

Page 1: ...ipment owner Lire soigneusement ces instructions avant l installation Conserver ce manuel port e de main pour r f rence ult rieure Ce manuel doit tre donn au propri taire de l quipement Lea cuidadosam...

Page 2: ...ur system TWO REMOTE CONTROLLERS CONTROL SYSTEM Confirm the following if your unit is the following control system type Two remote controllers control system Two remote controllers control one indoor...

Page 3: ...eath by suffocation WARNING Contact your dealer for repair and mainte nance Improper repair and maintenance may result in water leakage electric shock and fire Only use accessories made by Daikin that...

Page 4: ...hock Do not touch the air inlet or aluminum fin of the air conditioner as they can cut and cause injury Do not place objects in direct proximity of the outside unit Do not let leaves and other debris...

Page 5: ...ture WB Wet bulb temperature The setting temperature range of the remote con troller is 60 F to 90 F INSTALLATION SITE 4 Regarding places for installation Is the air conditioner installed at a well ve...

Page 6: ...7 DISPLAY UNDER CENTRAL IZED CONTROL When this display shows the system in UN DER CENTRALIZED CONTROL This is not a standard specification 8 DISPLAY FAN SPEED The display shows the fan speed L LOW H...

Page 7: ...onnection wire 8 Air outlet local procurement 9 COOLING HEATING AUTOMATIC FAN AND PROGRAM DRY OPERATION Operate in the following order 1 OPERATION MODE SELECTOR Press OPERATION MODE SELECTOR button se...

Page 8: ...ed setting temperature rises 1 F Each time this button is pressed setting temperature lowers 1 F The setting is impossible for fan operation NOTE The setting temperature range of the remote controller...

Page 9: ...use a dust proof cover local procurement Cleaning the inside of the indoor unit It is necessary to clean the inside of the indoor unit periodically Since the cleaning requires special technologies req...

Page 10: ...ER The following symptoms do not indicate air condi tioner malfunction THE SYSTEM DOES NOT OPERATE I The system does not restart immediately after the ON OFF button is pressed If the OPERATION lamp li...

Page 11: ...he unit blows out THE UNITS GIVE OFF ODORS VI The unit absorbs the smell of rooms furniture cigarettes etc and then emits them THE LIQUID CRYSTAL OF THE REMOTE VII CONTROLLER SHOW It happens immediate...

Page 12: ...rs Refer to HOW TO CLEAN THE AIR FILTER The system operates but it does not suffi 3 ciently cool or heat If the air inlet or outlet of the indoor or the outdoor unit is blocked with obstacles Remove t...

Page 13: ...3P250362 3A EM09A035 1006 HT 00_CV_3P250362 3A indd 2 00_CV_3P250362 3A indd 2 3 5 2010 9 07 50 AM 3 5 2010 9 07 50 AM...

Page 14: ...1 1 8 14 13 16 2 3 10 5 7 11 6 4 12 15 9 1 g h c e f a j d k i d b f k e 3 2 00_CV_3P250362 3A indd Sec 11 00_CV_3P250362 3A indd Sec 11 3 5 2010 9 07 50 AM 3 5 2010 9 07 50 AM...

Reviews: