3
5
• Split - Sky Air • RZAG-MV1
23
• Outdoor Unit • RZAG-MV1
5
Combination table
5 - 1
Combination Table
AZAS-MV1
AZAS-MY1
RZAG-MV1
RZAG-MY1
RZASG-MV1
RZASG-MY1
Possible combinations
P=
Pair
2=
Twin
3=
Triple
4=
Double twin
(*):
See note ·1·.
Duct (high
ESP)
F
C
AH
G
71
G
VEB
F
C
AH
G
10
0G
VEB
F
C
AH
G
12
5G
VEB
F
C
AH
G
14
0G
VEB
F
C
AG
35
AVEB
F
C
AG
50
AVEB
F
C
AG
60
AVEB
F
C
AG
71
AVEB
F
C
AG
10
0AVEB
F
C
AG
12
5AVEB
F
C
AG
14
0AVEB
F
F
A
35A
2V
E
B
F
F
A
50A
2V
E
B
F
F
A
60A
2V
E
B
F
B
A
35A
2V
E
B
F
B
A
50A
2V
E
B
F
B
A
60A
2V
E
B
F
B
A
71A
2V
E
B
F
B
A
100A
2V
E
B
F
B
A
125A
2V
E
B
F
B
A
140A
2V
E
B
F
N
A
35A
2V
E
B
F
N
A
50A
2V
E
B
F
N
A
60A
2V
E
B
F
U
A7
1AVEB
F
U
A1
00
AVEB
F
U
A1
25
AVEB
F
A
A7
1AU
VEB
F
A
A
100A
UV
E
B
F
D
A
125A
5V
E
B
RZAG71M7V1B
RZAG71M7Y1B
P
2
P
2
2
P
2
P
P
RZAG100M7V1B
RZAG100M7Y1B
P
3
2
P
3
2
3
2
P
3
2
P
P
RZAG125M7V1B
RZAG125M7Y1B
P
4
3
2
P
4
3
2
4
3
2
P
4
3
2
P
P
RZAG140M7V1B
RZAG140M7Y1B
2
P
4
3
2
P
4
3
4
3
2
P
4
3
2
2
RZASG71M2V1B
2
P
2
2
P
2
P
P
RZASG100M7V1B
RZASG100M7Y1B
3
2
P
3
2
3
2
P
3
2
P
P
RZASG125M7V1B
RZASG125M7Y1B
4
3
2
P
4
3
2
4
3
2
P
4
3
2
P
P
RZASG140M7V1B
RZASG140M7Y1B
4
3
2
P
4
3
4
3
2
P
4
3
2
2
AZAS71M2V1B
P
P
P
AZAS100M7V1B
AZAS100M7Y1B
P
P
P
AZAS125M7V1B
AZAS125M7Y1B
P
P
AZAS140M7V1B
AZAS140M7Y1B
P
P
F
VA71
AMVEB
F
VA10
0AMVEB
F
VA12
5AMVEB
F
VA14
0AMVEB
F
D
XM35F
3V1B
F
D
XM50F
3V1B
F
D
XM60F
3V1B
F
H
A35AVEB
F
H
A50AVEB
F
H
A60AVEB
F
H
A71AVEB
F
H
A100AVEB
F
H
A125AVEB
F
H
A140AVEB
RZAG71M7V1B
RZAG71M7Y1B
P
2
2
P
RZAG100M7V1B
RZAG100M7Y1B
P
3
2
3
2
P
RZAG125M7V1B
RZAG125M7Y1B
P
4
3
2
4
3
2
P
RZAG140M7V1B
RZAG140M7Y1B
2
P
4
3
4
3
2
P
RZASG71M2V1B
P
2
2
P
RZASG100M7V1B
RZASG100M7Y1B
P
3
2
3
2
P
RZASG125M7V1B
RZASG125M7Y1B
P
4
3
2
4
3
2
P
RZASG140M7V1B
RZASG140M7Y1B
2
P
4
3
4
3
2
P
AZAS71M2V1B
AZAS100M7V1B
AZAS100M7Y1B
AZAS125M7V1B
AZAS125M7Y1B
AZAS140M7V1B
AZAS140M7Y1B
Notes
1.
Maximum capacity is limited based on outdoor unit capacity.
2.
When combining multiple indoor units, designate the unit whose remote controller is equipped with the most functions as the master unit.
3.
For the selection of the correct refnet kit, required to install a multi-combination, refer to the option list.
Twin :
KHRQ(M)58T
Triple :
KHRQ(M)58H
Double twin :
KHRQ(M)58T
P
Model
AVA
125AMVE
Concealed floor
standing type
Ceiling-mounted -
4-way blow
Wall mounted type
Model
Sky Air
Floor standing type
Slim duct
Ceiling-suspended
Floor standing type
Sky Air
High Cassette
Thin cassette
2x2 cassette
Duct (medium ESP)
35+35+35 (*)
50+50+50 (*)
50+50+50 (*)
35+35+35+35 (*)
35+35+35+35
71
100
125
140
35+35
50+50
60+60
71+71
3D108868
RZAG-MV1
RZAG-MY1
Duct
(high
ESP)
F
C
A
HG71GV
E
B
F
C
A
HG100GV
E
B
F
C
A
HG125GV
E
B
F
C
A
HG140GV
E
B
F
C
AG
35
AVEB
F
C
AG
50
AVEB
F
C
AG
60
AVEB
F
C
AG
71
AVEB
F
C
AG
10
0AVEB
F
C
AG
12
5AVEB
F
C
AG
14
0AVEB
F
F
A
35A
2V
E
B
F
F
A
50A
2V
E
B
F
F
A
60A
2V
E
B
F
BA3
5A2
VEB
F
BA5
0A2
VEB
F
BA6
0A2
VEB
F
BA7
1A2
VEB
F
B
A
100A
2V
E
B
F
B
A
125A
2V
E
B
F
B
A
140A
2V
E
B
F
N
A
35A
2V
E
B
F
N
A
50A
2V
E
B
F
N
A
60A
2V
E
B
F
U
A7
1AVEB
F
U
A1
00
AVEB
F
U
A1
25
AVEB
F
AA7
1AU
V
EB
F
A
A
100A
UV
E
B
F
D
A125A5VEB
RZAG71M7V1B
RZAG71M7Y1B
P
3
2
P
3
2
3
2
P
P
P
RZAG100M7V1B
RZAG100M7Y1B
2
P
4
3
2
P
4
3
4
3
2
P
2
2
RZAG125M7V1B
RZAG125M7Y1B
2
P
4
3
2
P
4
3
4
3
2
P
2
2
RZAG140M7V1B
RZAG140M7Y1B
2
P
4
3
2
P
4
3
4
3
2
P
2
2
FVA71AMVEB
FVA100AMVEB
FVA125AMVEB
FVA140AMVEB
FDXM35F3V1B
FDXM50F3V1B
FDXM60F3V1B
FHA35AVEB
FHA50AVEB
FHA60AVEB
FHA71AVEB
FHA100AVEB
FHA125AVEB
FHA140AVEB
RZAG71M7V1B
RZAG71M7Y1B
P
3
2
3
2
P
RZAG100M7V1B
RZAG100M7Y1B
P
4
3
4
3
2
P
RZAG125M7V1B
RZAG125M7Y1B
P
4
3
4
3
2
P
RZAG140M7V1B
RZAG140M7Y1B
P
4
3
4
3
2
P
Possible combinations P= Pair
2= Twin
3= Triple
4= Double twin
Notes
1.
Maximum capacity is limited based on outdoor unit capacity.
2.
When combining multiple indoor units, designate the unit whose remote controller is equipped with the most functions as the master unit.
3.
For the selection of the correct refnet kit, required to install a multi-combination, refer to the option list.
Twin :
KHRQ(M)58T
Triple :
KHRQ(M)58H
Double twin :
KHRQ(M)58T
Model
Ceiling-mounted - 4-way
blow
Wall mounted
type
Model
Sky Air
Floor standing type
Slim duct
Ceiling-suspended
Sky Air
High Cassette
Thin cassette
2x2 cassette
Duct (medium ESP)
Concealed floor standing
type
3D108869