5 Technical data

Installation manual

11

AZQS100~14 AZQS100~140B7Y1B
Split system air conditioners
4P385528­1 – 2014.08

F1U~F8U

(140_V1)

▪ F1U~F4U: Fuse

▪ F6U: Fuse (T 5.0 A / 250 V)

▪ F7U, F8U: Fuse (F 1.0 A / 250 V)

F1U~F8U

(AZQS_Y1)

▪ F1U, F2U: Fuse (31.5 A / 250 V)

▪ F1U (A2P): Fuse (T 5.0 A / 250 V)

▪ F3U~F6U: Fuse (T 6.3 A / 250 V)

▪ F7U, F8U: Fuse (F 1.0 A / 250 V)

H1P~H7P

Light­emitting diode (service monitor is
orange)

HAP

Light­emitting diode (service monitor is
green)

K1M, K11M

Magnetic contactor

K1R

(AZQS_V1)

Magnetic relay (Y1S)

K1R

(AZQS_Y1)

▪ K1R (A1P): Magnetic relay (Y1S)

▪ K1R (A2P): Magnetic relay

K2R

(AZQS100_V1)

Magnetic relay

K2R

(AZQS_Y1)

▪ K2R  (A1P):  Magnetic  relay  (E1H

option)

▪ K2R (A2P): Magnetic relay

K10R, K13R~K15R

Magnetic relay

K4R

Magnetic relay E1H (option)

L1R~L3R

Reactor

M1C

Motor (compressor)

M1F

Motor (upper fan)

M2F

Motor (lower fan)

PS

Switching power supply

Q1DI

Earth leakage circuit breaker (field
supply)

R1~R6

Resistor

R1T

Thermistor (air)

R2T

Thermistor (discharge)

R3T

Thermistor (suction)

R4T

Thermistor (heat exchanger)

R5T

Thermistor (heat exchanger middle)

R6T

Thermistor (liquid)

R7T

(140_V1)

Thermistor (fin)

R7T, R8T

(AZQS100_V1)

Thermistor (Positive Temperature
Coefficient)

R10T

(AZQS_Y1)

Thermistor (fin)

RC

Signal receiver circuit

S1PH

High pressure switch

S1PL

Low pressure switch

TC

Signal transmission circuit

V1D~V4D

Diode

V1R

IGBT power module

V2R, V3R

Diode module

V1T~V3T

Insulated gate bipolar transistor (IGBT)

X6A

Connector (option)

X1M

Terminal strip

Y1E

Electronic expansion valve

Y1S

Solenoid valve (4­way valve)

Z1C~Z6C

Noise filter (ferrite core)

Z1F~Z6F

Noise filter

Symbols:

L

Live

N

Neutral

Field wiring

Terminal strip

Connector

Relay connector

Connection

Protective earth

Noiseless earth

Terminal

Option

Colours:

BLK

Black

BLU

Blue

BRN

Brown

GRN

Green

ORG

Orange

RED

Red

WHT

White

YLW

Yellow

Summary of Contents for Siesta

Page 1: ...Installation manual Split system air conditioners English Installation manual Split system air conditioners AZQS100B8V1B AZQS125B8V1B AZQS140B8V1B AZQS100B7Y1B AZQS125B7Y1B AZQS140B7Y1B...

Page 2: ...iivsete dokumentidega kui neid kasutatakse vastavalt meie juhenditele atitinka emiau nurodytus standartus ir arba kitus norminius dokumentus su s lyga kad yra naudojami pagal m s nurodymus tad ja liet...

Page 3: ...tdoor unit installation 9 3 6 1 To finish the outdoor unit installation 9 3 6 2 To check the insulation resistance of the compressor 9 4 Commissioning 9 4 1 Checklist before test run 9 4 2 To perform...

Page 4: ...ake sure that condensation water can be evacuated properly INFORMATION If necessary you can use a drain plug kit field supply to prevent drain water from dripping NOTICE If drain holes of the outdoor...

Page 5: ...piping a and the gas piping b Wind heat insulation around the curves and then cover it with vinyl tape c Make sure the field piping does not touch any compressor components d Seal the insulation ends...

Page 6: ...surize to 3000 kPa 30 bar in order to detect small leaks 2 Check for leaks by applying the bubble test solution to all connections 3 Discharge all nitrogen gas 3 3 3 To perform vacuum drying 1 Vacuum...

Page 7: ...F ELECTROCUTION WARNING ALWAYS use multicore cable for power supply cables CAUTION For use of units in applications with temperature alarm settings it is recommended to foresee a delay of 10 minutes f...

Page 8: ...unit NOTICE Follow the wiring diagram delivered with the unit located at the inside of the service cover Fix the earth wire to the stop valve attachment plate so that it does not slide Make sure the...

Page 9: ...edure is finished 1 M Insulation resistance is not OK Go to the next step 2 Turn ON the power and leave it on for 6 hours Result The compressor will heat up and evaporate any refrigerant in the compre...

Page 10: ...d switch two of the three electrical wires U4 or UF The inter unit branch wiring is not correct UA The outdoor and indoor unit are incompatible NOTICE The reversed phase protection detector of this pr...

Page 11: ...tor lower fan PS Switching power supply Q1DI Earth leakage circuit breaker field supply R1 R6 Resistor R1T Thermistor air R2T Thermistor discharge R3T Thermistor suction R4T Thermistor heat exchanger...

Page 12: ...4P385528 1 2014 08 Copyright 2014 Daikin 4P385528 1 0000000T...

Reviews: