Indoor unit quiet operation. When the airflow is set to
" ", the noise from the unit will be reduced.

Note:

  When  using 

Drying

  operation  or 

Fan  only

  mode,  you

CANNOT adjust the airflow rate setting.

To adjust the airflow rate

1

Press 

to  change  the  airflow  setting  in  the  following

sequence.

5.3.3

Airflow direction

When.

 Adjust the airflow direction as desired.

What.

  The  system  directs  the  airflow  differently,  depending  on  the

user selection (swinging or fixed position). It does so by moving the

vertical blades.

Setting

Airflow direction

 Vertical auto swing Moves up and down.

[—]

Stays in a fixed position.

CAUTION

▪ ALWAYS  use  a  user  interface  to  adjust  the  angles  of

the  flap.  When  the  flap  is  swinging  and  you  move  it

forcibly by hand, the mechanism will break.

▪ Be  careful  when  adjusting  the  louvers.  Inside  the  air

outlet, a fan is rotating at high speed.

Note:

  The  movable  range  of  the  flap  varies  according  to  the

operation  mode.  The  flap  will  stop  at  the  upper  position  when  the

airflow rate is changed to low during the up and down swing setting.

a

b

c

a

Flap range in cooling or drying operation

b

Flap range in heating operation

c

Flap range in fan only operation

To adjust the airflow direction

1

To use auto swing, press 

.

Result: 

 will appear on the LCD.

Result: 

The flap (horizontal blade) will begin to swing.

2

To  use  fixed  position,  press 

  when  the  flap  reaches  the

desired position.

Result: 

 disappears from the LCD.

To adjust the louvers (vertical blades)

1

Hold 1 or both knobs and move the louvers.

a

a

a

Knobs

INFORMATION

When  the  unit  is  installed  in  a  corner  of  a  room,  the

direction  of  the  louvers  should  be  facing  away  from  the

wall. Efficiency will drop if a wall blocks the air.

5.3.4

Comfort airflow operation

This operation can be used in 

Heating

 or 

Cooling

 operation mode.

It will provide a comfortable wind that will NOT come in direct contact

with people.

To start/stop Comfort airflow operation

INFORMATION

Powerful and Comfort airflow operation CANNOT be used

at the same time. The last selected function takes priority.

If the upper or lower direction is selected, Comfort airflow

operation will be cancelled.

1

Press 

 to start.

Result: 

The  flap  position  will  change, 

  is  displayed  on  the

LCD, and the airflow rate is set to automatic.

Mode

Position of flap…

Cooling/Drying

Up

Heating

Down

Note: 

Comfort airflow operation is NOT available in Fan only mode.

2

Press 

 to stop.

Result: 

The flap will return to the position from before the Comfort

airflow mode; 

 disappears from the LCD.

5.3.5

Powerful operation

This  operation  quickly  maximizes  the  cooling/heating  effect  in  any

operation mode. You can get the maximum capacity.

To start/stop Powerful operation

1

Press 

 to start.

Result: 

 is displayed on the LCD. Powerful operation runs

for 

20 

minutes; after that, operation returns to the previously set

mode.

Mode

Airflow rate

Cooling/Heating/Automatic

▪ To  maximize  the  cooling/

heating  effect,  the  capacity  of

outdoor unit is increased.

▪ The airflow rate is fixed to the

maximum setting.

The temperature and airflow

settings CANNOT be changed.

Drying

▪ The  temperature  setting  is

lowered by 2.5°C.

▪ The  airflow  rate  is  slightly

increased.

Summary of Contents for Siesta ATXP20L2V1B

Page 1: ...User reference guide Daikin room air conditioner English User reference guide Daikin room air conditioner ATXP20L2V1B ATXP25L2V1B ATXP35L2V1B...

Page 2: ...tom The units can give off odours 12 8 1 8 Symptom The outdoor fan rotates while the air conditioner is not in operation 12 8 2 Solving problems based on error codes 12 9 Disposal 13 10 Glossary 13 1...

Page 3: ...plete set consists of General safety precautions Safety instructions that you must read before operating your system Format Paper in the box of the indoor unit Operation manual Quick guide for basic u...

Page 4: ...Signal communication might be disabled if fluorescent lamps are in the room In that case contact your installer Other appliances If the user interface signals operate other appliances move the other a...

Page 5: ...the user interface Changing Fahrenheit or Celsius unit setting Turning on the power supply 4 2 To fix the user interface to the wall c b a 2 a User interface b Screw c User interface holder 1 Choose...

Page 6: ...a room to the temperature setpoint It automatically switches between cooling and heating if necessary Drying The system decreases the humidity in a room without changing the temperature Heating The s...

Page 7: ...djust the louvers vertical blades 1 Hold 1 or both knobs and move the louvers a a a Knobs INFORMATION When the unit is installed in a corner of a room the direction of the louvers should be facing awa...

Page 8: ...er reduce power consumption 5 3 7 ON OFF timer operation Timer functions are useful for automatically switching the air conditioner on off at night or in the morning You can also use OFF timer and ON...

Page 9: ...void excessive heating or cooling Notice that it may take some time for the room temperature to reach the set temperature Consider using the timer setting options Adjust the air flow direction to avoi...

Page 10: ...operation turn the breaker off or pull out the supply cord Otherwise an electric shock and injury may result 1 Clean with a soft cloth If it is difficult to remove stains use water or a neutral deter...

Page 11: ...oting If one of the following malfunctions occur take the measures shown below and contact your dealer WARNING Stop operation and shut off the power if anything unusual occurs burning smells etc Leavi...

Page 12: ...at are NOT system malfunctions The following symptoms are NOT system malfunctions 8 1 1 Symptom A sound like water flowing is heard This sound is caused by the refrigerant flowing in the unit This sou...

Page 13: ...lf the dismantling of the system treatment of the refrigerant oil and other parts MUST comply with applicable legislation Units MUST be treated at a specialised treatment facility for reuse recycling...

Page 14: ......

Page 15: ......

Page 16: ...4P513685 2 2017 11 Copyright 2017 Daikin...

Reviews: