background image

7 Maintenance and service

User reference guide

10

ATXP20~35L2V1B

Daikin room air conditioner

4P513685-2 – 2017.11

WARNING

To prevent electric shocks or fire:

▪ Do NOT rinse the unit.

▪ Do NOT operate the unit with wet hands.

▪ Do NOT place any objects containing water on the unit.

CAUTION

After  a  long  use,  check  the  unit  stand  and  fitting  for
damage. If damaged, the unit may fall and result in injury.

CAUTION

Do  NOT  touch  the  heat  exchanger  fins.  These  fins  are
sharp and could result in cutting injuries.

WARNING

Be carefull with ladders when working in high places.

7.2

To clean the indoor unit and user
interface

NOTICE

▪ Do  NOT  use  gasoline,  benzene,  thinner  polishing

powder  or  liquid  insecticide. 

Possible  consequence:

Discoloration and deformation.

▪ Do  NOT  use  water  or  air  of  40°C  or  higher. 

Possible

consequence: 

Discoloration and deformation.

▪ Do NOT use polishing compounds.

▪ Do 

NOT 

use 

scrubbing 

brush. 

Possible

consequence: 

The surface finishing peels off.

DANGER: RISK OF ELECTROCUTION

Before  cleaning,  be  sure  to  stop  the  operation,  turn  the
breaker  off  or  pull  out  the  supply  cord.  Otherwise,  an
electric shock and injury may result.

1

Clean  with  a  soft  cloth.  If  it  is  difficult  to  remove  stains,  use
water or a neutral detergent.

7.3

To clean the front panel

1

Clean  with  a  soft  cloth.  If  it  is  difficult  to  remove  stains,  use
water or a neutral detergent.

7.4

About the air filter

Operating the unit with dirty filters means that the filter:

▪ CANNOT deodorize the air,

▪ CANNOT clean the air,

▪ poor heating/cooling,

▪ causes odour.

To order titanium apatite deodorizing filters, contact your dealer.

Item

Part number

Titanium deodorizing filter
(without frame) 1 set

KAF970A46

7.5

To clean the air filters

1

Open the front panel.

2

Push the tab at the centre of each air filter, then pull it down.

3

Pull out the air filters.

1

2

4

Remove the titanium apatite deodorizing filter from the tabs.

5

Clean or replace each filter.

6

Wash  the  air  filters  with  water  or  clean  them  with  a  vacuum
cleaner.

7

Soak in lukewarm water for about 10 to 15 minutes.

8

Set the air filters and the titanium apatite deodorizing filter back
to their original position.

9

Close the front panel by pushing the claws of the filter into the
slots at 3 locations (left, right, middle).

Summary of Contents for Siesta ATXP20L2V1B

Page 1: ...User reference guide Daikin room air conditioner English User reference guide Daikin room air conditioner ATXP20L2V1B ATXP25L2V1B ATXP35L2V1B...

Page 2: ...tom The units can give off odours 12 8 1 8 Symptom The outdoor fan rotates while the air conditioner is not in operation 12 8 2 Solving problems based on error codes 12 9 Disposal 13 10 Glossary 13 1...

Page 3: ...plete set consists of General safety precautions Safety instructions that you must read before operating your system Format Paper in the box of the indoor unit Operation manual Quick guide for basic u...

Page 4: ...Signal communication might be disabled if fluorescent lamps are in the room In that case contact your installer Other appliances If the user interface signals operate other appliances move the other a...

Page 5: ...the user interface Changing Fahrenheit or Celsius unit setting Turning on the power supply 4 2 To fix the user interface to the wall c b a 2 a User interface b Screw c User interface holder 1 Choose...

Page 6: ...a room to the temperature setpoint It automatically switches between cooling and heating if necessary Drying The system decreases the humidity in a room without changing the temperature Heating The s...

Page 7: ...djust the louvers vertical blades 1 Hold 1 or both knobs and move the louvers a a a Knobs INFORMATION When the unit is installed in a corner of a room the direction of the louvers should be facing awa...

Page 8: ...er reduce power consumption 5 3 7 ON OFF timer operation Timer functions are useful for automatically switching the air conditioner on off at night or in the morning You can also use OFF timer and ON...

Page 9: ...void excessive heating or cooling Notice that it may take some time for the room temperature to reach the set temperature Consider using the timer setting options Adjust the air flow direction to avoi...

Page 10: ...operation turn the breaker off or pull out the supply cord Otherwise an electric shock and injury may result 1 Clean with a soft cloth If it is difficult to remove stains use water or a neutral deter...

Page 11: ...oting If one of the following malfunctions occur take the measures shown below and contact your dealer WARNING Stop operation and shut off the power if anything unusual occurs burning smells etc Leavi...

Page 12: ...at are NOT system malfunctions The following symptoms are NOT system malfunctions 8 1 1 Symptom A sound like water flowing is heard This sound is caused by the refrigerant flowing in the unit This sou...

Page 13: ...lf the dismantling of the system treatment of the refrigerant oil and other parts MUST comply with applicable legislation Units MUST be treated at a specialised treatment facility for reuse recycling...

Page 14: ......

Page 15: ......

Page 16: ...4P513685 2 2017 11 Copyright 2017 Daikin...

Reviews: