background image

9 Disposal

User reference guide

13

ATXP20~35L2V1B
Daikin room air conditioner
4P513685-2 – 2017.11

INFORMATION

▪ A  short  beep  and  2  consecutive  beeps  indicate  non-

corresponding codes.

▪ To  cancel  the  code  display,  hold  the 

  cancel

button for 5 seconds. The code will also disappear from
the  display  if  the  button  is  NOT  pressed  within
1 minute.

System

Error code

Description

Normal

Refrigerant shortage

Overvoltage detection

Signal transmission error (between indoor and
outdoor unit)

Indoor/outdoor unit combination fault

Indoor unit

Error code

Description

Indoor unit PCB abnormality

Freeze-up protection or high-pressure control

Fan motor (DC motor) abnormality

Indoor heat exchanger thermistor abnormality

Room temperature thermistor abnormality

Outdoor unit

Error code

Description

4-way valve abnormality

Outdoor unit PCB abnormality

Overload activation (compressor overload)

Compressor lock

DC fan lock

Input power overcurrent

Discharge pipe temperature control

High-pressure control (in cooling)

Compressor system sensor abnormality

Position sensor abnormality

DC voltage / current sensor abnormality

Outdoor temperature thermistor abnormality

Discharge pipe thermistor abnormality

Outdoor heat exchanger thermistor abnormality

Electrical parts heat error

Radiation fin temperature rise

Inverter instantaneous overcurrent (DC)

Radiation fin thermistor abnormality

9

Disposal

NOTICE

Do  NOT  try  to  dismantle  the  system  yourself:  the
dismantling  of  the  system,  treatment  of  the  refrigerant,  oil
and  other  parts  MUST  comply  with  applicable  legislation.
Units  MUST  be  treated  at  a  specialised  treatment  facility
for reuse, recycling and recovery.

10

Glossary

DHW = Domestic hot water

Hot  water  used,  in  any  type  of  building,  for  domestic
purposes.

LWT = Leaving water temperature

Water temperature at the water outlet of the heat pump.

Dealer

Sales distributor for the product.

Authorized installer

Technical  skilled  person  who  is  qualified  to  install  the
product.

User

Person  who  is  owner  of  the  product  and/or  operates  the
product.

Applicable legislation

All  international,  European,  national  and  local  directives,
laws,  regulations  and/or  codes  that  are  relevant  and
applicable for a certain product or domain.

Service company

Qualified  company  which  can  perform  or  coordinate  the
required service to the product.

Installation manual

Instruction  manual  specified  for  a  certain  product  or
application, explaining how to install, configure and maintain
it.

Operation manual

Instruction  manual  specified  for  a  certain  product  or
application, explaining how to operate it.

Accessories

Labels, manuals, information sheets and equipment that are
delivered  with  the  product  and  that  need  to  be  installed
according  to  the  instructions  in  the  accompanying
documentation.

Optional equipment

Equipment  made  or  approved  by  Daikin  that  can  be
combined  with  the  product  according  to  the  instructions  in
the accompanying documentation.

Field supply

Equipment NOT made by Daikin that can be combined with
the  product  according  to  the  instructions  in  the
accompanying documentation.

Summary of Contents for Siesta ATXP20L2V1B

Page 1: ...User reference guide Daikin room air conditioner English User reference guide Daikin room air conditioner ATXP20L2V1B ATXP25L2V1B ATXP35L2V1B...

Page 2: ...tom The units can give off odours 12 8 1 8 Symptom The outdoor fan rotates while the air conditioner is not in operation 12 8 2 Solving problems based on error codes 12 9 Disposal 13 10 Glossary 13 1...

Page 3: ...plete set consists of General safety precautions Safety instructions that you must read before operating your system Format Paper in the box of the indoor unit Operation manual Quick guide for basic u...

Page 4: ...Signal communication might be disabled if fluorescent lamps are in the room In that case contact your installer Other appliances If the user interface signals operate other appliances move the other a...

Page 5: ...the user interface Changing Fahrenheit or Celsius unit setting Turning on the power supply 4 2 To fix the user interface to the wall c b a 2 a User interface b Screw c User interface holder 1 Choose...

Page 6: ...a room to the temperature setpoint It automatically switches between cooling and heating if necessary Drying The system decreases the humidity in a room without changing the temperature Heating The s...

Page 7: ...djust the louvers vertical blades 1 Hold 1 or both knobs and move the louvers a a a Knobs INFORMATION When the unit is installed in a corner of a room the direction of the louvers should be facing awa...

Page 8: ...er reduce power consumption 5 3 7 ON OFF timer operation Timer functions are useful for automatically switching the air conditioner on off at night or in the morning You can also use OFF timer and ON...

Page 9: ...void excessive heating or cooling Notice that it may take some time for the room temperature to reach the set temperature Consider using the timer setting options Adjust the air flow direction to avoi...

Page 10: ...operation turn the breaker off or pull out the supply cord Otherwise an electric shock and injury may result 1 Clean with a soft cloth If it is difficult to remove stains use water or a neutral deter...

Page 11: ...oting If one of the following malfunctions occur take the measures shown below and contact your dealer WARNING Stop operation and shut off the power if anything unusual occurs burning smells etc Leavi...

Page 12: ...at are NOT system malfunctions The following symptoms are NOT system malfunctions 8 1 1 Symptom A sound like water flowing is heard This sound is caused by the refrigerant flowing in the unit This sou...

Page 13: ...lf the dismantling of the system treatment of the refrigerant oil and other parts MUST comply with applicable legislation Units MUST be treated at a specialised treatment facility for reuse recycling...

Page 14: ......

Page 15: ......

Page 16: ...4P513685 2 2017 11 Copyright 2017 Daikin...

Reviews: