![Daikin SiEN04-306D Service Manual Download Page 47](http://html1.mh-extra.com/html/daikin/sien04-306d/sien04-306d_service-manual_4211034047.webp)
Printed Circuit Board Connector Wiring Diagram
SiEN04-306D
38
Printed Circuit Board Connector Wiring Diagram
1.2
Outdoor Unit
Connectors
Note:
Other Designations
1) S10, AC2, HL
Connector for terminal strip
2) S20
Connector for electronic expansion valve coil
3) S31, S32
Connector for SPM
4) S33, S71
Connector for MID
5) S34, S52, S72, S102
CN11, CN14
HAC1, HE1
Connector for control PCB
6) S40
Connector for overload protector
7) S51, S101
Connector for service monitor PCB
8) S70
Connector for fan motor
9) S80
Connector for four way valve coil
10) S90
Connector for thermistors
(outdoor air, heat exchanger, and discharge pipe)
11) S91
Connector for fin thermistor
12) AC1, E
Connector for power supply PCB
13) H1, H2
Connector for diode bridge
14) HE2
Connector for earth
15) L1, L2
Connector for reactor
1) FU1
Fuse (30A)
2) FU2, FU201
Fuse (3.15A)
3) LED A
Service monitor LED
4) SW1
Forced operation ON/OFF switch
5) SW4
Field setting switch
*Switch B is for the changeover of the lower limit for
cooling. (OFF: –10°C, ON: –15°C)
Refer to page 70 for detail.
6) V3
Varistor
Summary of Contents for SiEN04-306D
Page 109: ...Instruction SiEN04 306D 100 System Configuration...
Page 199: ...Outdoor Unit SiEN04 306D 190 Removal Procedure...
Page 203: ...Others SiEN04 306D 194 Others...
Page 214: ...SiEN04 306D Wiring Diagrams Appendix 205 FTKD18 24 28BVMS...