![Daikin SiEN04-306D Service Manual Download Page 113](http://html1.mh-extra.com/html/daikin/sien04-306d/sien04-306d_service-manual_4211034113.webp)
Service Check Function
SiEN04-306D
104
Service Diagnosis
3. Service Check Function
In the ARC433A series remote control, the temperature display sections on the main unit
indicate corresponding codes.
Check Method 1
1. When the timer cancel button is held down for 5 seconds, a “00” indication flashes on the
temperature display section.
2. Press the timer cancel button repeatedly until a continuous beep is produced.
The code indication changes in the sequence shown below, and notifies with a long beep.
Note:
1. A short beep and two consecutive beeps indicate non-corresponding codes.
2. To cancel the code display, hold the timer cancel button down for 5 seconds. The code
display also cancels itself if the button is not pressed for 1 minute.
No.
Code
No.
Code
No.
Code
1
00
12
C7
23
H0
2
U4
13
H8
24
E1
3
F3
14
J3
25
P4
4
E6
15
A3
26
L3
5
L5
16
A1
27
L4
6
A6
17
C4
28
H6
7
E5
18
C5
29
H7
8
F6
19
H9
30
U2
9
C9
20
J6
31
UH
10
U0
21
UA
32
EA
11
E7
22
A5
33
AH
<
ARC433A21, A22
>
(R2839)
C
O N
TEMP
ON/OFF
POWERFUL
HOME LEAVE
MODE
TIMER
FAN
SILENT
SWING
ON
CANCEL
OFF
SENSOR
TIMER CANCEL button
It cancels the timer setting.
Summary of Contents for SiEN04-306D
Page 109: ...Instruction SiEN04 306D 100 System Configuration...
Page 199: ...Outdoor Unit SiEN04 306D 190 Removal Procedure...
Page 203: ...Others SiEN04 306D 194 Others...
Page 214: ...SiEN04 306D Wiring Diagrams Appendix 205 FTKD18 24 28BVMS...
Page 216: ...SiEN04 306D Wiring Diagrams Appendix 207 RKD18 24 28BVMS...