![Daikin SiEN04-306D Service Manual Download Page 175](http://html1.mh-extra.com/html/daikin/sien04-306d/sien04-306d_service-manual_4211034175.webp)
Outdoor Unit
SiEN04-306D
166
Removal Procedure
2. Outdoor Unit
2.1
Removal of the Panels and Plates
Procedure
Warning
Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Step
Procedure
Points
1. Remove the panels and
plates.
Take care not to cut your
finger by the fins of the heat
exchanger.
1
Loosen the four screws
and lift the top panel.
2
Loosen the four screws
and remove the
discharge grille.
Top p
a
nel
(R2676)
O
u
tdoor
a
ir thermi
s
tor
He
a
t
exch
a
nger
(R2677)
Di
s
ch
a
rge grille
(R267
8
)
Summary of Contents for SiEN04-306D
Page 109: ...Instruction SiEN04 306D 100 System Configuration...
Page 199: ...Outdoor Unit SiEN04 306D 190 Removal Procedure...
Page 203: ...Others SiEN04 306D 194 Others...
Page 214: ...SiEN04 306D Wiring Diagrams Appendix 205 FTKD18 24 28BVMS...
Page 216: ...SiEN04 306D Wiring Diagrams Appendix 207 RKD18 24 28BVMS...