![background image](http://html1.mh-extra.com/html/daikin/rzqsg-l3-9v1/rzqsg-l3-9v1_technical-data-manual_2460036015.webp)
3
2
• Split - Sky Air • RZQSG-L3/9V1
13
• Outdoor Unit • RZQSG-L3/9V1
2
Specifications
Seasonal efficiency
(according to
EN14825)
Cooling
Energy label
A+
A
Pdesign
kW
6.80
9.50
12.00
SEER
5.81
5.61
5.30
Annual energy consumption
kWh
410
593
793
A Condition (35°C - 27/
19)
Pdc
kW
6.80
9.50
12.00
EERd
3.21
2.65
power input
kW
-
2.96
4.53
B Condition (30°C - 27/
19)
Pdc
kW
5.01
7.00
8.84
EERd
3.86
3.73
3.01
power input
kW
-
1.88
2.94
C Condition (25°C - 27/
19)
Pdc
kW
3.65
4.59
5.69
EERd
7.91
7.23
7.33
power input
kW
-
0.64
0.78
D Condition (20°C - 27/
19)
Pdc
kW
3.81
4.02
3.96
EERd
10.81
9.63
10.43
power input
kW
-
0.42
0.38
Heating (Average
climate)
Energy label
A
A+
A
Pdesign
kW
6.33
7.60
SCOP/A
3.90
4.01
3.85
SCOPnet/A
-
4.02
3.86
Pdh Heating capacity at -10°
-
7
Annual energy consumption
kWh
2,273
2,654
2,764
Required back up heating cap at design conditions
kW
0.63
0.56
0.55
TOL
Tol (temperature operating
limit)
°C
-15
Pdh (declared heating cap)
kW
5.87
7.56
7.60
COPd (declared COP)
1.73
1.89
1.88
Power input
kW
-
4.00
4.05
TBivalent
Tbiv (bivalent temperature)
°C
-7
Pdh (declared heating cap)
kW
5.60
6.72
COPd (declared COP)
2.44
2.69
2.62
Power input
kW
-
2.50
2.57
A Condition (-7°C)
Pdh (declared heating cap)
kW
5.60
6.72
COPd (declared COP)
2.44
2.69
2.62
Power input
kW
-
2.50
2.57
B Condition (2°C)
Pdh (declared heating cap)
kW
3.46
4.13
4.14
COPd (declared COP)
3.88
3.82
3.68
Power input
kW
-
1.09
1.13
C Condition (7°C)
Pdh (declared heating cap)
kW
2.86
3.02
3.03
COPd (declared COP)
5.41
5.56
5.26
Power input
kW
-
0.55
0.58
D Condition (12°C)
Pdh (declared heating cap)
kW
3.25
3.44
3.46
COPd (declared COP)
6.31
6.59
6.24
Power input
kW
-
0.53
0.56
Pto (Thermostat off)
W
7.0
Cooling
Psb (Standby mode cooling)
W
7.0
Cdc (Degradation cooling)
0.25
Heating
Psb (Standby mode heating)
W
-
7.0
Cdh (Degradation heating)
0.25
Pck (Crankcase heater mode)
W
0.0
Poff (Off mode)
W
0.0
Cooling function included
Yes
Heating function included
Yes
Average climate included
Yes
Cold season included
No
Warm season included
No
Ecolabel logo
No
2-6 Capacity and Power input
FUQ71C/
RZQSG71L3V1
FUQ100C/
RZQSG100L9V1
FUQ125C/
RZQSG125L9V1
Summary of Contents for RZQSG-L3/9V1
Page 1: ...Air Conditioning Technical Data RZQSG L3 9V1...
Page 2: ......