Installation manual
18
RXYSQ4~Y1B
VRVIII-S System air conditioner
4PW68122-1 – 02.2011
10. E
LECTRICAL
WIRING
WORK
10.1. Internal wiring – Parts table
L .............................Live
N ............................Neutral
...........Field wiring
.....................Terminal strip
..........................Connector
.........................Protective earth (screw)
..........................Connection
.......................Relay connector
............................Functional earthing
...........................Terminal
..........................Movable connector
..........................Fixed connector
BLU ........................Blue
BRN .......................Brown
GRN .......................Green
RED .......................Red
WHT .......................White
YLW .......................Yellow
ORG .......................Orange
BLK ........................Black
A1P ........................Printed circuit board (main)
A2P ........................Printed circuit board (inverter)
A3P ................ *......Printed circuit board (noise filter)
A4P ................ *......Printed circuit board (C/H selector)
BS1~BS5 ...............Push button switch (mode, set, return, test,
reset)
C1~C3....................Capacitor
C4 .................. *......Capacitor
DS1 ........................DIP switch
E1HC .....................Crankcase heater
F1U, F4U........ *......Fuse (T 6.3 A/250 V)
F1U (A1P) ..... #......Fuse (T 6.3 A/250 V)
F3U (A1P) ..... #......Fuse (T 6.3 A/250 V)
F4U (A1P) ..... #......Fuse (T 6.3 A/250 V)
F6U ................ *......Fuse (T 5.0 A/250 V)
FINTH ............ *......Thermistor (fin)
H1P~H8P ...............Light emitting diode (service monitor orange)
Prepare, test: blinking
H2P ........................Malfunction detection: light up
HAP................ *......Light emitting diode (service monitor green)
HAP (A1P) .... #......Light emitting diode (service monitor green)
HAP (A2P)..... # ..... Light emitting diode (service monitor green)
K1M ................* ..... Magnetic contactor (M1C)
K1M (A1P)..... # ..... Magnetic contactor
K1R ....................... Magnetic relay (Y1S)
K2R ....................... Magnetic relay (Y2S)
K3R ....................... Magnetic relay (Y3S)
K4R ....................... Magnetic relay (E1HC)
K5R ....................... Magnetic relay
K6R ............... # ..... Magnetic relay
L1R........................ Reactor
M1C....................... Motor (compressor)
M1F ....................... Motor (fan) (upper)
M2F ....................... Motor (fan) (lower)
PS.......................... Switching power supply
Q1DI ...................... Field earth leakage breaker (300 mA)
R1...................* ..... Resistor (current limiting)
R1 (A1P)........ # ..... Resistor
R1 (A2P)........ # ..... Resistor
R2...................* ..... Resistor (current sensor)
R2 (A2P)........ # ..... Resistor
R1T........................ Thermistor (air)
R2T.................* ..... Thermistor (discharge)
R2T................ # ..... Thermistor (M1C discharge)
R3T........................ Thermistor (suction 1)
R4T.................* ..... Thermistor (heat exchanger)
R4T................ # ..... Thermistor (subcool)
R5T........................ Thermistor (suction 2)
R6T.................* ..... Thermistor (subcooling heat exchanger)
R6T................ # ..... Thermistor (heat exchanger)
R7T.................* ..... Thermistor (liquid pipe)
R7T................ # ..... Thermistor (liquid pipe 1)
R8T........................ Thermistor (liquid pipe 2)
R9T................ # ..... Thermistor (power module)
S1NPH .................. Pressure sensor (high)
S1NPL ................... Pressure sensor (low)
S1PH ..................... Pressure switch (high)
V1R ....................... Power module
V2R, V3R............... Diode module
V1T.................* ..... IGBT (Insulated Gate Bipolar Transistor)
X1M ....................... Terminal strip (power supply)
X1M ................* ..... Terminal strip (C/H selector) (A4P)
X2M ................* ..... Terminal strip (control)
X2M ............... # ..... Terminal strip (control) (cool/heat selector)
Y1E........................ Electronic expansion valve (main)
Y3E........................ Electronic expansion valve (subcool)
Y1S........................ Solenoid valve (4 way valve)
Y2S........................ Solenoid valve (hot gas)
Y3S........................ Solenoid valve (unload circuit)
Z1C~Z8C........* ..... Noise filter (ferrite core)
Z1C~Z4C....... # ..... Noise filter (ferrite core)
Z1F~Z4F ........* ..... Noise filter
Z1F ................ # ..... Noise filter (with surge absorber)
Z2F ................ # ..... Noise filter
■
All wiring must be performed by an authorized
electrician.
■
All field supplied components and all electric
construction should comply with the applicable local
and national codes.
To persons in charge of electrical wiring work:
Do not operate the unit until the refrigerant piping is
complete. (Running it before the piping is ready will break
the compressor.)