background image

 

RXYQ8~1 RXYQ8~12P7YLK
VRVIII system air conditioner

Operation manual

 

3

 

2.

W

 

HAT

 

 

 

TO

 

 

 

DO

 

 

 

BEFORE

 

 

 

OPERATION

 

This operation manual is for the following systems with standard
control. Before initiating operation, contact your dealer for the
operation that corresponds to your system type and mark.

If your installation has a customized control system, ask your dealer
for the operation that corresponds to your system.

Outdoor units 

(See figure 3)

Names and functions of parts 

(See figure 3)

(

figure 3

 shows system with cool/heat selectors.)

 

3.

R

 

EMOTE

 

 

 

CONTROLLER

 

 

NAME

 

 

 

AND

 

 

 

FUNCTION

 

 

 

OF

 

 

 

EACH

 

 

 

BUTTON

 

 

 

AND

 

 

 

ICON

 

(See figure 1)

 

1

 

ON/OFF BUTTON

Press the ON/OFF button to start or stop the system.

 

2

 

OPERATION LAMP (RED)

The operation lamp lights up during operation or blinks if a
malfunction occurs.

 

3

 

ICON "

" (CHANGEOVER UNDER CONTROL)

It is not possible to changeover heating/cooling with the remote
controller when this icon is shown.

 

4

 

ICON "

" (AIR FLOW DIRECTION)

Refer to the chapter 

"6.3. Adjusting the air flow direction" on

page 5

.

 

5

 

ICON "

" (VENTILATION/AIR CLEANING)

This icon shows that the ventilation units are in operation.

 

6

 

ICON "

"

 

 

 

(SET TEMPERATURE)

This icon shows the set temperature.

 

7

 

ICON "

"

 

 

 

"

"

 

 

 

"

"

 

 

 

"

"  "

"

 

 

 

(OPERATION MODE)

This icon shows the actual operation mode.

 

8

 

ICON "

" PROGRAMMED TIME)

This icon shows the programmed time of the system start or
stop.

 

9

 

ICON "

" (INSPECTION/TEST OPERATION)

When the inspection/test operation button is pressed, the icon
shows the actual mode of the system.

 

10

 

ICON "

" (UNDER CENTRALISED CONTROL)

This icon indicates that the change-over of the installation is
under centralised control. (This is not a standard specification)

 

11

 

ICON "

" (FAN SPEED)

This icon indicates the set fan speed.

 

12

 

ICON "

" (TIME TO CLEAN THE AIR FILTER)

This icon indicates the air filter must be cleaned. Refer to the
manual of the indoor unit.

 

13

 

ICON "

" (DEFROST/HOT START)

This icon indicates that the defrost/hotstart mode is active. Refer
to the chapter 

"Explanation of heating operation" on page 4

.

 

14

 

TIMER MODE START/STOP BUTTON

Refer to the chapter 

"6.4. Programming start and stop of the

system with timer" on page 5

.

 

15

 

TIMER ON/OFF BUTTON

Refer to the chapter 

"6.4. Programming start and stop of the

system with timer" on page 5

.

 

16

 

INSPECTION/TEST OPERATION BUTTON

Not used, for service purposes only.

 

17

 

PROGRAMMING TIME BUTTON

Use this button for setting the programming start or stop time.

 

18

 

TEMPERATURE SETTING BUTTON

Use this button for setting the desired temperature.

 

19

 

FILTER SIGN RESET BUTTON

This button is used to reset the air filter cleaning time icon. Refer
to the operation manual of the indoor unit.

 

20

 

FAN SPEED CONTROL BUTTON

Use this button to select the fan speed of your preference.

 

21

 

OPERATION MODE SELECTOR BUTTON

Use this button to select the operation mode of your preference.

 

22

 

AIR FLOW DIRECTION ADJUST BUTTON

This button enables to adjust the air flow direction. Refer to the
chapter 

"6.3. Adjusting the air flow direction" on page 5

.

 

23

 

TERMISTOR

The termistor senses the room temperature around the remote
controller.

 

24

 

These buttons are used when the ventilation units are installed
(these are optional accessories)

Refer to the operation manual of the ventilation units.

Refer to the operation manual of the remote controller.

 

4.

C

 

HANGEOVER

 

 

 

SWITCH

 

: N

 

AME

 

AND

 

FUNCTION

 

OF

 

EACH

 

SWITCH

 

(See figure 2)

1

FAN ONLY/AIR CONDITIONING SELECTOR SWITCH

Set the switch to 

 for fan only operation or to 

 for heating or

cooling operation.

2

COOL/HEAT CHANGEOVER SWITCH

Set the switch to 

 for cooling or to 

 for heating operation.

Cool/heat slector

Operation modes

Heat pumps RXYQ series

 yes

 no

1

Outdoor unit

2

Indoor unit

3

Remote controller

4

Inlet air

5

Outlet air

6

Cool/heat selector

NOTE

In contradiction to actual operating situations, the
display on 

figure 1

  shows all passible indications

on the remote controller with its cover opened.

For FXS, FXM, FXL and FXN units, the air flow
direction adjust button is not available, the display
shows "NOT AVAILABLE" when pressed anyway.

4PW41759-1A – 08.2011

Summary of Contents for RXYQ8P7Y1K

Page 1: ...OPERATION MANUAL RXYQ8P7Y1K RXYQ10P7Y1K RXYQ12P7Y1K RXYQ8P7YLK RXYQ10P7YLK RXYQ12P7YLK System air conditioner...

Page 2: ...1 6 2 1 1 6 3 1 10 11 1 1 8 3 5 4 2 7 2 4 3 1 5 1 2 3 4 2 1 2 9 C D A B 13 2 1 5 5 3 4 6 4 3 4 2 1 1 12 1 2 4 3 10 11 12 18 5 13 23 6 14 15 8 9 7 16 17 19 20 21 22 24 1 2 3 4 2 1 1 2 3 4 5 6 1 6 2 6 3...

Page 3: ...e spray such as hair spray lacquer or paint near the unit It may cause a fire Never touch the air outlet or the horizontal blades while the swing flap is in operation Fingers may become caught or the...

Page 4: ...he air conditioner at any place where flammable gas may leak out If the gas leaks out and stays around the air conditioner a fire may break out In order to avoid electric shock or fire make sure that...

Page 5: ...e Refer to the chapter Explanation of heating operation on page 4 14 TIMER MODE START STOP BUTTON Refer to the chapter 6 4 Programming start and stop of the system with timer on page 5 15 TIMER ON OFF...

Page 6: ...ng the system 6 Press the on off button once again The operation lamp goes off and the system stops operation Explanation of heating operation It may take longer to reach the set temperature for gener...

Page 7: ...d fixed air flow direction setting Movement of the air flow flap See figure 9 For the following conditions a micro computer controls the air flow direction which may be different from the display The...

Page 8: ...roller controls up to 16 indoor units All indoor units are equally set Two remote controller control system Two remote controllers control one indoor unit in case of group control system one group of...

Page 9: ...4 The fan strength does not correspond to the setting The fan strength does no change even if the fan strength adjustment button in pressed During heating operation when the room temperature reaches...

Page 10: ...aker or an earth leakage breaker frequently actuates or the ON OFF switch does not properly work Measure Turn off the main power switch If water leaks from the unit Measure Stop the operation The oper...

Page 11: ...e is long sites with 24 hour air conditioning Recommended replacement cycle of wear parts Table 2 Replacement Cycle list Contact your dealer for details Moving and discarding the unit Contact your dea...

Page 12: ...Copyright 2008 Daikin 4PW41759 1A 08 2011...

Reviews: