background image

 

Operation manual

 

2

 

RXYQ8~1 RXYQ8~12P7YLK

VRVIII system air conditioner

 

 

Consult the dealer if the air conditioner submerges owing to a
natural disaster, such as a flood or typhoon.
Do not operate the air conditioner in that case, or otherwise a
malfunction, electric shock, or fire may result.

 

 

Do not start or stop operating the air conditioner with the power
supply breaker turned ON or OFF.
Otherwise, fire or water leakage may result. Furthermore, the
fan will rotate abruptly if power failure compensation is enabled,
which may result in injury.

 

 

Do not use the product in the atmosphere contamined with oil
vapor, such as cooking oil or machine oil vapor.
Oil vapor may cause crack damage, electric shocks, or fire.

 

 

Be sure to use a dedicated power supply for the air conditioner.
The use of any other power supply may cause heat generation,
fire or product failures.

 

Cautions

 

 

Do not use the air conditioner for other purposes.
In order to avoid any quality deterioration, do not use the unit for
cooling precision instruments, food, plants, animals or works of
art.

 

 

In order to avoid injury, do not remove the fan guard of the
outdoor unit.

 

 

To  avoid oxygen deficiency, ventilate the room sufficiently if
equipment with burner is used together with the air conditioner.

 

 

After a long use, check the unit stand and fitting for damage.
If damaged, the unit may fall and result in injury.

 

 

Do not place a flammable spray bottle near the air conditioner
and do not use sprays.
Doing so may result in a fire.

 

 

Before cleaning, be sure to stop the operation, turn the breaker
off or pull out the supply cord.
Otherwise, an electric shock and injury may result.

 

 

Do not operate the air conditioner with a wet hand.
An electric shock may result.

 

 

Do not place items which might be damaged by moisture under
the indoor unit.
Condensation may form if the humidity is above 80%, if the drain
outlet is blocked or the filter is polluted.

 

 

Do not place appliances which produce open fire in places
exposed to the air flow from the unit or under the indoor unit. It
may cause incomplete combustion or deformation of the unit
due to the heat.

 

 

Do not allow anyone to mount on the outdoor unit or avoid
placing any object on it.
Falling or tumbling may result in injury.

 

 

Never expose little children, plants or animals directly to the air
flow.
Adverse influence to little children, animals and plants may
result.

 

 

Do not wash the air conditioner with water.
Electric shock or fire may result.

 

 

Do not install the air conditioner at any place where flammable
gas may leak out.
If the gas leaks out and stays around the air conditioner, a fire
may break out.

 

 

In order to avoid electric shock or fire, make sure that an earth
leak detector is installed.

 

 

Be sure the air conditioner is electrically earthed.
In order to avoid electric shock, make sure that the unit is
grounded and that the earth wire is not connected to gas or
water pipe, lightning conductor or telephone earth wire.

 

 

Arrange the drain hose to ensure smooth drainage. Incomplete
drainage may cause wetting of the building, furniture etc.

 

 

Do not let children play on and around the outdoor unit.
If they touch the unit carelessly, it may result in injury.

 

 

Do not place a flower vase or anything containing water on the
unit.
Water may enter the unit, causing an electric shock or fire.

 

 

Do not place the controller exposed to direct sunlight.
The LCD display may get discolored, failing to display the data.

 

 

Do not wipe the controller operation panel with benzine, thinner,
chemical dustcloth, etc.
The panel may get discolored or the coating peeled off. If it is
heavily dirty, soak a cloth in water-diluted neutral detergent,
squeeze it well and wipe the panel clean. Wipe it with another
dry cloth.

 

 

Never touch the internal parts of the controller.
Do not remove the front panel. Some parts inside are dangerous
to touch and a machine trouble may happen. For checking and
adjusting the internal parts, contact your dealer.

 

 

Avoid placing the controller in a spot splashed with water.
Water coming inside the machine may cause an electric leak or
may damage the internal electronic parts.

 

 

Do not operate the air conditioner when using a room fumigation
- type insecticide.
Failure to observe could cause the chemicals to become
deposited in the unit, which could endanger the health of those
who are hypersensitive to chemicals.

 

 

Do not touch the heat exchanger fins.
These fins are sharp and could result in cutting injuries.

 

 

The appliance is not intended for use by young children or infirm
persons without supervision.

 

 

Young children should be supervised to ensure that they do not
play with the appliance.

 

 

Do not block air inlets nor outlets.
Impaired air flow may result in insufficient performance or
trouble.

 

 

Consult your dealer regarding cleaning the inside of the air
conditioner.
Improper cleaning may cause breakage of plastic parts, water
leakage and other damage as well as electric shocks.

 

 

Watch your steps when you clean the air filter or when you
inspect the unit.
If high-place work is required, utmost attention must be paid.
If the scaffold is unstable, you may fall or topple down, thus
causing injury.

4PW41759-1A – 08.2011

Summary of Contents for RXYQ8P7Y1K

Page 1: ...OPERATION MANUAL RXYQ8P7Y1K RXYQ10P7Y1K RXYQ12P7Y1K RXYQ8P7YLK RXYQ10P7YLK RXYQ12P7YLK System air conditioner...

Page 2: ...1 6 2 1 1 6 3 1 10 11 1 1 8 3 5 4 2 7 2 4 3 1 5 1 2 3 4 2 1 2 9 C D A B 13 2 1 5 5 3 4 6 4 3 4 2 1 1 12 1 2 4 3 10 11 12 18 5 13 23 6 14 15 8 9 7 16 17 19 20 21 22 24 1 2 3 4 2 1 1 2 3 4 5 6 1 6 2 6 3...

Page 3: ...e spray such as hair spray lacquer or paint near the unit It may cause a fire Never touch the air outlet or the horizontal blades while the swing flap is in operation Fingers may become caught or the...

Page 4: ...he air conditioner at any place where flammable gas may leak out If the gas leaks out and stays around the air conditioner a fire may break out In order to avoid electric shock or fire make sure that...

Page 5: ...e Refer to the chapter Explanation of heating operation on page 4 14 TIMER MODE START STOP BUTTON Refer to the chapter 6 4 Programming start and stop of the system with timer on page 5 15 TIMER ON OFF...

Page 6: ...ng the system 6 Press the on off button once again The operation lamp goes off and the system stops operation Explanation of heating operation It may take longer to reach the set temperature for gener...

Page 7: ...d fixed air flow direction setting Movement of the air flow flap See figure 9 For the following conditions a micro computer controls the air flow direction which may be different from the display The...

Page 8: ...roller controls up to 16 indoor units All indoor units are equally set Two remote controller control system Two remote controllers control one indoor unit in case of group control system one group of...

Page 9: ...4 The fan strength does not correspond to the setting The fan strength does no change even if the fan strength adjustment button in pressed During heating operation when the room temperature reaches...

Page 10: ...aker or an earth leakage breaker frequently actuates or the ON OFF switch does not properly work Measure Turn off the main power switch If water leaks from the unit Measure Stop the operation The oper...

Page 11: ...e is long sites with 24 hour air conditioning Recommended replacement cycle of wear parts Table 2 Replacement Cycle list Contact your dealer for details Moving and discarding the unit Contact your dea...

Page 12: ...Copyright 2008 Daikin 4PW41759 1A 08 2011...

Reviews: