![background image](http://html1.mh-extra.com/html/daikin/rxr28ev1b8/rxr28ev1b8_service-manual_2459934005.webp)
Si001275
Heater Assembly / Humidifying Rotor / Humidifying Rotor Motor
Removal Procedure
3
2. Heater Assembly / Humidifying Rotor /
Humidifying Rotor Motor
Warning
Be sure to wait for 10 minutes or more after turning off all power supplies before
disassembling work.
Step
Procedure
Points
1. Remove the heater
assembly.
1
Remove the 4 screws
and remove the duct on
adsorption side.
2
Release the lead wire
for the humidifying
rotor motor from the
hooks.
3
Remove the 2 screws
and remove the heater
assembly.
The heater assembly should
be replaced as an assembly
set. (Disassembling of the
assembly may cause
malfunction.)
2. Remove the humidifying
rotor.
1
Release the fan motor
lead wire from the
hooks.
(R18766)
Duct on adsorption side
Heater assembly
(R18767)
Humidifying rotor motor
(R5800)
(R18768)
Fan motor lead wire
Hook
Hook