![background image](http://html1.mh-extra.com/html/daikin/rxr28ev1b8/rxr28ev1b8_service-manual_2459934023.webp)
Si001275
Reactor / Partition Plate
Removal Procedure
21
11.Reactor / Partition Plate
Warning
Be sure to wait for 10 minutes or more after turning off all power supplies before
disassembling work.
Step
Procedure
Points
1. Remove the reactor.
1
Remove the screw and
remove the reactor.
2. Remove the partition plate.
1
Remove the 2 screws.
2
Lift the partition plate
and remove it.
When reassembling, make
sure to catch the lower hook
of the partition plate.
(R18484)
Reactor
(R14025)
Partition plate
(R5884)