![background image](http://html1.mh-extra.com/html/daikin/rxl12qmvju/rxl12qmvju_service-manual_2459917013.webp)
Si001655E
Electrical Box / PCB
Removal Procedure
11
2. Remove the PCB.
1
Remove the earth /
ground screw.
2
3
Remove the 5 screws
of the PCB.
Unfasten the 2 spacers
and the 3 hooks from
the PCB.
4
Remove the PCB.
Step
Procedure
Points
Earth / ground screw
(R20402)
Hook
Hook
Spacer
(R20403)
PCB
(R20404)