Si001655E
Thermistor ASSY
Removal Procedure
13
4
Remove the 2 screws
and open the conduit
mounting plate cover to
the left, then remove it.
The conduit mounting plate
cover has a hook on the left
and a projection on top. Be
sure to catch them all when
reassembling.
5
Remove the 7 screws
on the terminal board
and disconnect the
connecting wire and the
power supply wire.
6
Pull out the outdoor
temperature thermistor
holder.
Step
Procedure
Points
Projection
Conduit
mounting
plate cover
Hook
(R21632)
Projection
Hook
(R20409)
Connecting wire
Power supply
wire
Terminal
board
(R21633)
Outdoor temperature thermistor holder