4

English

c.Where sulfured gas exists such as a hot-spring 

resort

d.Where there are considerable voltage fluctua-

tions such as a factory or plant

e.Vehicles and vessels

 

f

 

.Where there is much spray of oil and vapor such 

as a cookery, etc.

g.Where there are machines generating electro-

magnetic waves

h.Filled with acid and/or alkaline steam or vapor

• Is a snow protection measure taken?

For details, consult your dealer.

Regarding wiring

• All wiring must be performed by an authorized 

electrician.

To do wiring, ask your dealer. Never do it by yourself.

• Make sure that a separate power supply circuit 

is provided for this air conditioner and that all 
electrical work is carried out by qualified per-
sonnel according to local laws and regulations.

Pay attention to running noises, too

• Are the following places selected?

a.A place that can sufficiently withstand the 

weight of the air conditioner with less running 
noises and vibrations.

b.A place where the hot wind discharged from the 

air outlet of the outdoor unit and the running 
noises.

• Are you sure that there are no obstacles near 

the air outlet of the outdoor unit?

Such obstacles may result in declined perfor-
mance and increased running noises.

• If abnormal noises occur in use, consult your 

dealer.

Regarding drainage of drain piping

• Is the drain piping executed to perform com-

plete drainage?

If proper drainage is not carried out from the out-
door drain pipes during air-conditioning operation, 
chances are that dust and dirt are clogged in the 
pipe. This may result in a water leakage from the 
indoor unit. Under such circumstances, stop the 
operation of the air conditioner, and then consult 
your dealer or our service station.

Read the operation manual that came with 
the remote controller.

Operating procedure varies with heat pump type 
and cooling only type. Contact your Daikin dealer 
to confirm your system type.

5. OPERATION PROCEDURE

To protect the unit, turn on the main power switch 
6 hours before operation.

If the main power supply is turned off during oper-
ation, operation will restart automatically after the 
power turns back on again.

[EXPLANATION OF HEATING OPERATION]

DEFROST OPERATION

As the frost on the coil of an outdoor unit increase, 
heating effect decreases and the system goes 
into DEFROST OPERATION.

The indoor unit fan stops and the remote control-
ler display shows “

”.

After 6 to 8 minutes (maximum 10 minutes) of 
DEFROST OPERATION, the system returns to 
HEATING OPERATION.

Regarding outside air temperature and heat-
ing capacity

The heating capacity of the air conditioner 
declines as the outside air temperature falls. In 
such a case, use the air conditioner in combina-
tion with other heating systems.

A warm air circulating system is employed, and 
therefore it takes some time until the entire room 
is warmed up after the start of operation.

An indoor fan runs to discharge a gentle wind 
automatically until the temperature inside the air 
conditioner reaches a certain level. At this time, 
the remote controller displays “

”. Leave it 

as it stands and wait for a while.

When the warm air stays under the ceiling and 
your feet are cold, we recommend that you use a 
circulator (a fan to circulate the air inside the 
room). For details, consult your dealer.

AIR FLOW DIRECTION ADJUST

There are 2 ways of adjusting the air discharge 
angle.

A. UP AND DOWN DIRECTION

Press the AIR FLOW DIRECTION ADJUST 
button to select the air direction as shown 
below.

A. Up and down adjustment

B. Left and right direction

Summary of Contents for RQ100

Page 1: ...English Deutsch Fran ais Espa ol Italiano Nederlands Portugues SPLIT SYSTEM Air Conditioner OPERATION MANUAL MODELS Wall mounted type FAQ100BUV1B FAQ100BVV1B...

Page 2: ...l acondicionador de aire Dicho manual le indicar c mo utilizar adec uadamente la m quina y le ayudar en caso de aver a Despu s de leer el manual cons rvelo para consultas futuras Funcionamiento consul...

Page 3: ...1 b d f k e i h a j d f g e c...

Page 4: ...gerante aceite y otros componentes debe ser efectuado por un instalador competente de acuerdo con las normas locales y nacionales aplicables Los acondicionadores de aire deben ser tratados en instalac...

Page 5: ...s operation system Cooling only type This system provides cooling program dry and fan operation modes PRECAUTIONS FOR GROUP CONTROL SYSTEM OR TWO REMOTE CONTROLLER CONTROL SYSTEM This system provides...

Page 6: ...sult in a water leakage electric shock and fire Ask your dealer to move and reinstall the air conditioner Incomplete installation may result in a water leakage electric shock and fire Do not use any f...

Page 7: ...making contact with electrical parts Never touch the internal parts of the remote controller Do not remove the front panel Some parts inside are dangerous to touch and a machine trouble may happen Fo...

Page 8: ...d then consult your dealer or our service station Read the operation manual that came with the remote controller Operating procedure varies with heat pump type and cooling only type Contact your Daiki...

Page 9: ...le environment Avoid excessive heating or cooling Prevent direct sunlight from entering a room dur ing cooling operation by using curtains or blinds Ventilate the room regularly Using the unit for lon...

Page 10: ...press AIR FILTER CLEANING TIME ICON RESET BUTTON The display vanishes HOW TO CLEAN AIR OUTLET AND OUTSIDE PANELS Clean with soft cloth When it is difficult to remove stains use water or neutral deterg...

Page 11: ...erated by the temperature regu lator working It will quiet down after about a minute A continuous flow Shuh sound is heard when the systems is in COOLING or DEFROST OPERATION This is the sound of refr...

Page 12: ...ked by obstacles Remove the obstacle and make it well venti lated Check if the air filter is clogged Ask a qualified service person to clean the air filters Refer to MAINTENANCE OPERATION lamp INSPECT...

Page 13: ...3P184442 7B EM03A092D 0704 HT FS...