background image

2

English

• The precautions described below are WARN-

ING and CAUTION. These are very important 
precautions concerning safety. Be sure to 
observe all of them without fail.

WARNING

..These are the matters with possi-

bilities leading to serious conse-
quences such as death or serious 
injury due to erroneous handling.

CAUTION

....These are the matters with possi-

bilities leading to injury or material 
damage due to erroneous han-
dling including probabilities lead-
ing to serious consequences in 
some cases.

• After reading, keep this manual at a place 

where any user can read at any time. Further-
more, make certain that this operation manual 
is handed to a new user when he takes over 
the operation.

WARNING

Avoid exposure of your body directly to the 
cold air for a long time, or avoid excessive 
exposure of your body to the cold air.

Otherwise, your physical condition may be dete-
riorated and/or your health may be ruined.

When the air conditioner is in abnormal con-
ditions (smell of something burning, etc), 
unplug the power cord from the outlet, and 
contact the dealer where you purchased the 
air conditioner.

Continued operation under such circumstances 
may result in a failure, electric shock, and fire.

Ask your dealer for installation of the air con-
ditioner.

Incomplete installation performed by yourself may 
result in a water leakage, electric shock, and fire.

Ask your dealer for improvement, repair, and 
maintenance.

Incomplete improvement, repair, and maintenance 
may result in a water leakage, electric shock, and fire.

Do not insert your finger, a stick, etc., into the 
air inlet, outlet, and fan blades.

A fan in high-speed running may result in injury.

For refrigerant leakage, consult your dealer.

When the air conditioner is to be installed in a 
small room, it is necessary to take proper mea-
sures so that the amount of any leaked refriger-
ant does not exceed the limiting concentration 
even when it leaks. If the refrigerant leaks 
exceeding the level of limiting concentration, an 
oxygen deficiency accident may happen.

For installation of separately sold compo-
nent parts, ask a specialist.

Be sure to use the separately sold component 
parts designated by our company.
Incomplete installation performed by yourself may 
result in a water leakage, electric shock, and fire.

Ask your dealer to move and reinstall the air 
conditioner.

Incomplete installation may result in a water 
leakage, electric shock, and fire.

Do not use any fuse with improper capacity.

The use of a piece of wire and whatnot may 
result in a failure and fire.

The refrigerant in the air conditioner is safe 
and normally does not leak. If the refrigerant 
leaks inside the room, the contact with a fire 
of a burner, a heater or a cooker may result in 
a harmful gas.

Do not use the air conditioner until when a ser-
vice person confirms to finish repairing the por-
tion where the refrigerant leaks.

Be sure to establish an earth.

Do not earth the unit to a utility pipe, arrester, or 
telephone earth. 
Incomplete earth may cause electrical shock, or fire. 
A high surge current from lightning or other 
sources may cause damage to the air conditioner.

Be sure to install an earth leakage breaker.

Failure to install an earth leakage breaker may 
result in electric shocks, or fire.

Consult the dealer if the air conditioner sub-
merges owing to a natural disaster, such as a 
flood or typhoon.

Do not operate the air conditioner in that case, or 
otherwise a malfunction, electric shock, or fire 
may result.

CAUTION

Do not use the air conditioner for other purposes.

Do not use the air conditioner for a special appli-
cation such as the storage of foods, animals and 
plants, precision machines, and art objects as 
otherwise the deterioration of quality may result.

Do not remove the air outlet of the outdoor unit.

The fan may get exposed and result in injury.

When the air conditioner is used in combina-
tion with burners or heaters, perform suffi-
cient ventilation.

Insufficient ventilation may result in an oxygen 
deficiency accident.

Check and make sure that foundation blocks 
are not damaged after a long use.

If they are left in a damaged condition, the unit 
may fall and result in injury.

Neither place a flammable spray bottle near 
the air conditioner nor perform spraying.

Doing so may result in a fire.

To clean the air conditioner, stop operation, 
and unplug the power cord from the outlet.

Otherwise, an electric shock and injury may result.

Do not operate the air conditioner with a wet 
hand.

An electric shock may result.

Do not place items that might be damaged by 
water under the indoor unit.

Water may condensate and drip if the humidity 
reaches 80% or if the drain exit gets clogged.

Summary of Contents for RQ100

Page 1: ...English Deutsch Fran ais Espa ol Italiano Nederlands Portugues SPLIT SYSTEM Air Conditioner OPERATION MANUAL MODELS Wall mounted type FAQ100BUV1B FAQ100BVV1B...

Page 2: ...l acondicionador de aire Dicho manual le indicar c mo utilizar adec uadamente la m quina y le ayudar en caso de aver a Despu s de leer el manual cons rvelo para consultas futuras Funcionamiento consul...

Page 3: ...1 b d f k e i h a j d f g e c...

Page 4: ...gerante aceite y otros componentes debe ser efectuado por un instalador competente de acuerdo con las normas locales y nacionales aplicables Los acondicionadores de aire deben ser tratados en instalac...

Page 5: ...s operation system Cooling only type This system provides cooling program dry and fan operation modes PRECAUTIONS FOR GROUP CONTROL SYSTEM OR TWO REMOTE CONTROLLER CONTROL SYSTEM This system provides...

Page 6: ...sult in a water leakage electric shock and fire Ask your dealer to move and reinstall the air conditioner Incomplete installation may result in a water leakage electric shock and fire Do not use any f...

Page 7: ...making contact with electrical parts Never touch the internal parts of the remote controller Do not remove the front panel Some parts inside are dangerous to touch and a machine trouble may happen Fo...

Page 8: ...d then consult your dealer or our service station Read the operation manual that came with the remote controller Operating procedure varies with heat pump type and cooling only type Contact your Daiki...

Page 9: ...le environment Avoid excessive heating or cooling Prevent direct sunlight from entering a room dur ing cooling operation by using curtains or blinds Ventilate the room regularly Using the unit for lon...

Page 10: ...press AIR FILTER CLEANING TIME ICON RESET BUTTON The display vanishes HOW TO CLEAN AIR OUTLET AND OUTSIDE PANELS Clean with soft cloth When it is difficult to remove stains use water or neutral deterg...

Page 11: ...erated by the temperature regu lator working It will quiet down after about a minute A continuous flow Shuh sound is heard when the systems is in COOLING or DEFROST OPERATION This is the sound of refr...

Page 12: ...ked by obstacles Remove the obstacle and make it well venti lated Check if the air filter is clogged Ask a qualified service person to clean the air filters Refer to MAINTENANCE OPERATION lamp INSPECT...

Page 13: ...3P184442 7B EM03A092D 0704 HT FS...

Reviews: