![background image](http://html1.mh-extra.com/html/daikin/rotex-hpsu-bi-bloc-ultra/rotex-hpsu-bi-bloc-ultra_installation-manual_4699568007.webp)
4 Installation
Installation manual
7
RRGA04~08DAV3
ROTEX HPSU Bi-Bloc Ultra
4P496756-1B – 2018.07
300
600
<150
<150
(mm)
>300
100
a
b
0 mm
a
Maximum snowfall height
b
EKFT008D option kit
Option 4: On brackets to the wall with the EKFT008D option kit
The EKFT008D option kit is recommended in areas with heavy
snowfall.
>250
>300
>250
(mm)
a
b
c
4×
a
Maximum snowfall height
b
EKFT008D option kit
c
Anti-vibration rubber (field supply)
4.2.2
To install the outdoor unit
CAUTION
Do NOT remove the protective cardboard before the unit is
installed properly.
1
Lift the outdoor unit as described in
.
2
Install the outdoor unit as follows:
▪ (1) Put the unit into position (using the sling to the left and
the handle to the right).
▪ (2) Remove the sling (by pulling 1 side of the sling).
▪ (3) Fix the unit.
2×
3
2
1
a
a
a
Air outlet
NOTICE
Properly align the unit. Make sure the backside of the unit
does NOT protrude.
3
Remove the protective cardboard and instruction sheet.
a
b