6 Technical data

Installation manual

12

RRGA04~08DAV3

ROTEX HPSU Bi-Bloc Ultra

4P496756-1B – 2018.07

M1F

Fan

R1T

Thermistor (outdoor air)

R2T

Thermistor (heat exchanger)

R3T

Thermistor (compressor discharge)

S1PH

High pressure switch (automatic reset)

Y1E

Electronic expansion valve

Y1S

Solenoid valve (4‑way valve)(ON: cooling)
Heating
Cooling

Summary of Contents for ROTEX HPSU Bi-Bloc Ultra

Page 1: ...Installation manual ROTEX HPSU Bi Bloc Ultra English Installation manual ROTEX HPSU Bi Bloc Ultra RRGA04DAV3 RRGA06DAV3 RRGA08DAV3...

Page 2: ...ektyw n urma prevederilor 19 20 21 22 23 24 25 ob upo tevanju dolo b vastavalt n uetele laikantis nuostat pateikiam iev rojot pras bas kas noteiktas odr iavaj c ustanovenia bunun ko ullar na uygun ola...

Page 3: ...S vastaava kyll stysl mp tila M C Kylm aine N Varmuuspainelaitteen asetus P bar Valmistusnumero ja valmistusvuosi katso mallin nimikilpi Maxim ln p pustn tlak PS K bar Minim ln maxim ln p pustn teplot...

Page 4: ...To finish the outdoor unit installation 11 5 Starting up the outdoor unit 11 6 Technical data 11 6 1 Piping diagram Outdoor unit 11 6 2 Wiring diagram Outdoor unit 13 1 About the documentation 1 1 Abo...

Page 5: ...following spacing guidelines 1200 250 250 250 350 350 mm mm a b b a a Air outlet b Air inlet INFORMATION In sound sensitive areas e g near a bedroom you can install the low sound cover EKLN08A1 to de...

Page 6: ...ectrical wiring on the outdoor unit on page 10 4 2 Mounting the outdoor unit 4 2 1 To provide the installation structure This topic shows different installation structures For all use 4 sets of M8 or...

Page 7: ...ti vibration rubber field supply 4 2 2 To install the outdoor unit CAUTION Do NOT remove the protective cardboard before the unit is installed properly 1 Lift the outdoor unit as described in 2 1 1 To...

Page 8: ...al of the drain pan heater Non heated drain tube When using the drain pan heater without drain tube or with a non heated drain tube remove the drain hole insulation Item c on the illustration INFORMAT...

Page 9: ...essure Then Does not change There is no moisture in the system This procedure is finished Increases There is moisture in the system Go to the next step 3 Vacuum the system for at least 2 hours to a ma...

Page 10: ...e multicore cable for power supply cables 4 6 1 About electrical compliance Only for RRGA04 08DAV3 Equipment complying with EN IEC 61000 3 12 European International Technical Standard setting the limi...

Page 11: ...ice cover 5 Starting up the outdoor unit See the indoor unit installation manual for configuration and commissioning of the system 6 Technical data 6 1 Piping diagram Outdoor unit R2T 7 0 CuT 7 0 CuT...

Page 12: ...Bi Bloc Ultra 4P496756 1B 2018 07 M1F Fan R1T Thermistor outdoor air R2T Thermistor heat exchanger R3T Thermistor compressor discharge S1PH High pressure switch automatic reset Y1E Electronic expansio...

Page 13: ...YLW yellow 3 Legend AL Connector C Capacitor DB Rectifier bridge DC Connector DP Connector E Connector F1U Fuse T 6 3 A 250 V FU1 FU2 Fuse T 3 15 A 250 V FU3 Fuse T 30 A 250 V H Connector IPM Intelli...