23
5.6
Flue and air supply duct
For the installation of the flue and air supply duct material, see the
manual included with the materials. Contact the
manufacturer of the relevant flue and air supply duct materials for
extensive technical information and specific
assembly instructions.
Make sure that the socket connections of the flue and air supply duct
materials are correctly sealed.
Improper fastening of the flue and the air supply duct
can lead to hazardous situations or result in personal injury.
Check all flue components for tightness.
Don not use screws or parkers to mount the flue system as leakage can
occur.
Do not use any sort of grease when mounting the pipe system.
Use water instead. The sealing rubbers can be negatively affected when
grease is applied.
Do not mix any components, materials or ways of coupling from
different manufacturers.
5.6.1
Concentric connection 60/100
The boiler is fitted with a flue gas adapter suitable for connecting to a concentric flue gas extractor
system with a diameter of 60/100.
Fit the concentric pipe thoughtfully in the adapter. The built in gaskets ensure there is an air tight
seal.
5.6.2
Concentric connection 80/125
If required, the flue gas adapter 60/100 can be replaced by a version for a flue gas extractor
system with a 80/125 diameter.
1.
Carefully follow the instruction as provided with the adapter set 80/125.
2.
Fit the concentric pipe thoughtfully in the adapter. The built in gaskets ensure there is an air
tight seal.
5.6.3
Parallel connection 80/80
If required, the flue gas adapter 60/100 can be replaced by a version for a parallel flue system (2
pipes) with a 80 mm diameter.
1.
Carefully follow the instruction as provided with the adapter set 80.
2.
Fit the pipes for the air supply and flue gas thoughtfully in the air inlet opening and flue gas
adapter of the unit. The built in gaskets ensure there is an air tight seal. Make sure that the
connections are not mixed.