32
FA ROTEX A1 BOe - 02/2014
7
x
Oil burner
URS12
Conversion kit for the output range 12-14 kW.
15 46 15
URS20
Conversion kit for the output range 20-24 kW.
15 46 24
URS25e
Conversion kit for the output range 25-27 kW.
15 46 29
URS35e
Conversion kit for the output range 33-34 kW.
15 46 36
7.3.2 Instructions for burner setting
The oil burner is factory-set for a certain output range
(see tab. 7-1, values printed in bold).
To change the burner output:
– Change the pump pressure,
– Adjust air quantity,
– Distance oil nozzle / air nozzle setting (tab. 7-1, dimension
"Y"),
– if big adjustment has been made to output: change oil nozzle
and air nozzle (changeover kit).
Conversion kit
To set some output ranges, a conversion kit URS is needed
(see tab. 7-1).
Certain changeover sets also contain, in addition to a suitable oil
nozzle, an air nozzle with a different flow cross-section
(see section 7.5).
Oil nozzles
For retention of the minimum emission values ROTEX recom-
mends using the
Danfoss
oil nozzles of the
Type 80° H
(see tab. 7-1).
Unit type
(Burner type)
Boiler
-output
Air
nozzle
Oil nozzle
Danfoss
80°H
Oil pump
pressure
Oil
throughput
Distance
oil/air
nozzle
Air
throttle
Fan
pressure
Conversion
kit
kW
Ø / mm
USgal/h
(GpH)
bar
kg/h
Dimension
Y/mm
%
mbar
Type
A1 BO 15-e
(oil blue burner BLB
15e)
12
17.5
0.30
10.5
1.05
0
§
10
§
5.3
URS12
13
17.5
0.30
12.5
1.14
0
§
14
§
6.5
14
17.5
0.30
14.0
1.23
0
§
18
§
7.5
15
17.5
0.35
10.0
1.32
1
§
18
§
7.1
Series status
A1 BO 20-e
(oil blue burner BLB
20e)
12
19
0.30
10.5
1.05
3
§
64
§
4.5
URS12
13
19
0.30
13.0
1.14
3
§
68
§
5.0
14
19
0.30
15.5
1.23
4
§
80
§
5.7
15
19
0.40
10.0
1.32
4
§
20
§
6.3
Series status
16
19
0.40
11.5
1.41
4
§
23
§
7.2
17
19
0.40
13.0
1.49
4
§
26
§
7.9
18
19
0.40
14.5
1.58
4
§
29
§
8.5
19
19
0.40
16.5
1.67
4
§
41
§
9.4
20
19
0.40
18.0
1.75
4
§
100
§
10.4
A1 BO 27-e
(oil blue burner BLB
27e)
20
22
0.50
11.3
1.77
4
§
32
§
7.4
URS20
21
22
0.50
12.7
1.86
4
§
40
§
7.9
22
22
0.50
14.0
1.92
4
§
60
§
8.6
23
22
0.50
15.4
1.98
4
§
90
§
9.2
24
22
0.50
16.8
2.10
4
§
100
§
8.6
25
24
0.55
11.5
2.16
4
§
44
§
6.9
Series status
26
24
0.55
13.0
2.25
4
§
66
§
7.8
27
24
0.55
14.0
2.34
4
§
100
§
8.9
A1 BO 34-e
(oil blue burner BLB
34e)
25
24
0.55
14.5
2.19
5
§
25
§
7.2
URS25e
26
24
0.55
16.7
2.28
5
§
29
§
7.8
27
24
0.60
11.5
2.37
2
§
30
§
6.7
Series status
28
24
0.60
13.0
2.48
4
§
34
§
6.5
29
24
0.60
13.5
2.55
4
§
46
§
7.0
30
24
0.60
14.5
2.65
4
§
50
§
7.5
31
24
0.60
15.5
2.72
4
§
70
§
7.8
32
24
0.60
16.5
2.81
4
§
78
§
8.1
33
27
0.65
13.0
2.90
4
§
36
§
6.2
URS35e
34
27
0.65
13.7
2.99
4
§
40
§
6.7
Tab. 7-1 Set values of the ROTEX A1 BO for room-air dependent operation