Time settings for one switching cycle in one weekday or
block programme are also adopted for other time
periods, provided that they affect the same weekdays.
Examples referring to tab. 3-8:
a) For the single working day "Monday" the start time
in the 1st. Switching cycle changed from 06:00 to
05:00.
In the time period "Working week" and "Entire
week", the 1st. time block Switching cycle also
changed from 06:00 to 05:00.
b) For the time period "Weekend", the start time in the
1st. Switching cycle changed from 07:00 to 08:00.
In the individual weekdays "Saturday" and "Sun-
day", the 1st. time block is automatically Switch-
ing cycle also changed from 07:00 to 08:00.
c) For the time period "Entire week", the end time in
the 1st. time block Switching cycle changed from
22:00 to 21:30.
In all the weekdays the 1st. switching cycle is
also changed from 22:00 to 21:30.
Operating instructions
14
Daikin RoCon HP
Daikin Control
008.1420844 – 05/2014
3
x
Operation
–
2 timer programmes for the hot water circuit
, each with 3
possible switching cycles
– [DHW Program 1]
– [DHW Program 2]
The setting and input structure of the timer programmes
are identical to the ones for the heating circuit timer pro-
gramme (see also tab. 3-8).
–
1 timer programme for one optionally connected
circula-
tion pump with 3 individual possible switching cycles
[Circulation Time]
The setting and input structure of the timer programmes
are identical to the ones for the heating circuit timer pro-
gramme (see also tab. 3-8).
For further instructions concerning settings for an op-
tional circulation pump, see section 3.6.15.
Saved switching time programmes can be changed at any time.
To provide a better overview, we recommend making a record of
the programmed switching times and keeping it in a safe place
(see chapter 8.1.1).
The permanent timer programmes are preset as per tab. 3-9.
Switching cycle 1
Switching cycle 2
Switching cycle 3
Time period
On
Off
On
Off
On
Off
Room heating / Room cooling
Temperature setting
[T-Room 1 Setpoint]: 20 °C
[T-Room 2 Setpoint]: 20 °C
[T-Room 3 Setpoint]: 20 °C
[T-Reduced]: 10 °C
"HC Program 1"
Monday - Friday
06:00
22:00
- - : - -
- - : - -
- - : - -
- - : - -
Saturday, Sunday
07:00
23:00
- - : - -
- - : - -
- - : - -
- - : - -
"HC Program 2"
Monday - Friday
06:00
08:00
- - : - -
- - : - -
- - : - -
- - : - -
Saturday, Sunday
07:00
23:00
- - : - -
- - : - -
- - : - -
- - : - -
Domestic hot water generation
Temperature setting
[T-DHW Setpoint 1]: 48 °C
[T-DHW Setpoint 2]: 48 °C
[T-DHW Setpoint 3]: 48 °C
"DHW Program 1"
Monday - Sunday
00:00
24:00
- - : - -
- - : - -
- - : - -
- - : - -
"DHW Program 2"
Monday - Friday
05:00
21:00
- - : - -
- - : - -
- - : - -
- - : - -
Saturday, Sunday
06:00
22:00
- - : - -
- - : - -
- - : - -
- - : - -
"Circulation Time"
Monday - Friday
05:00
21:00
- - : - -
- - : - -
- - : - -
- - : - -
Saturday, Sunday
06:00
22:00
- - : - -
- - : - -
- - : - -
- - : - -
Tab. 3-9 Factory setting for the permanent switching time programmes