Wiring (1)
1) Do not use spliced wires, stranded wires (
CAUTION
(1)
), extension cords, or starburst connections, as
they may cause overheating, electrical shock, or fire. Follow all local, and state electrical codes.
2) Do not use locally purchased electrical parts inside the product. (Do not branch the power for the drain
pump, etc., from the terminal block.) Doing so may cause electric shock or fire.
3) Be sure to install an earth leak detector. (One that can handle higher harmonics.)
(This unit uses an inverter, which means that it must be used an earth leak detector capable handling
harmonics in order to prevent malfunctioning of the earth leak detector itself.)
4) Use an all-pole disconnection type breaker with at least 1/8 inch (3mm) between the contact point gaps.
5) When carrying out wiring connection, take care not to pull at the conduit.
6) Do not connect the power wire to the indoor unit. Doing so may cause electric shock or fire.
WARNING
<Method of Mounting Conduit>
Pass wires through the conduit and secure them with a lock nut.
Wire retainer
Conduit mounting plate
Service port
Lock nut
Conduit
Conduit mounting plate