Outdoor Unit: 09/12 Class
SiUS041111
180
Removal Procedure
3
Cut the clamp.
4
Remove the 3 screws
and remove the reactor.
5
Disconnect the 3
connectors for the filter
PCB [S10], [HN3],
[HL3].
Step
Procedure
Points
(R11780)
Reactor
(R11777)
[S10]
[HN3]
[HL3]