Indoor Unit: 09/12 Class
SiUS041111
136
Removal Procedure
2
Disconnect the
connector for the fan
motor [S200].
Release the fan motor
harnesses from the
hook.
3
Remove the screw of
the electrical box.
4
Slide the electrical box
to the right first and
detach the horizontal
blade from the electrical
box.
5
Pull the electrical box.
There is a hook on the bottom
frame. When reassembling, fit
the rear side of the electrical box
to the hook.
Step
Procedure
Points
(R11642)
[S200]
(R14602)
Hook
(R11643)
(R11644)
(R11657)
Hook
Bottom frame