Removal Procedure
3. Remove the thermistor
ASSY.
Be careful not to lose the clip
for the thermistor.
1
Cut the clamp.
2
Pull out the outdoor
heat exchanger
thermistor.
3
Slightly open the sound
blanket (outer) and the
sound blanket (top
upper).
Be careful not to lose the
fixture for the thermistor.
4
Detach the discharge
pipe thermistor and
remove the thermistor
ASSY.
Step
Procedure
Points
Clamp
Outdoor heat
exchanger thermistor
(R21712)
Clip
(R3264)
Sound blanket
(top upper)
Discharge pipe
thermistor
Sound blanket
(outer)
(R21713)
Fixture
(R21715)
Thermistor
ASSY
(R21714)