Si001653EA
Electrical Box / PCB
Removal Procedure
7
4
Disconnect the
connector [S20].
[S20]: electronic expansion
valve coil
5
Disconnect the
connector [S90] and
pull out the clamp.
[S90]: thermistors
6
Disconnect the relay
connector for
compressor and
remove the harness
from the wire clip.
When reassembling, make
sure the compressor
harness passes through the
wire clip.
Step
Procedure
Points
[S20]
(R22838)
[S90]
Clamp
(R22839)
Wire clip
Relay connector for compressor