![background image](http://html1.mh-extra.com/html/daikin/rkm20qvma/rkm20qvma_service-manual_2459836013.webp)
Si001653EA
Suction Grille / Protection Net / Thermistor ASSY
Removal Procedure
11
5
6
Remove the 7 screws
on the terminal board
and disconnect the
connecting wire and the
power supply wire.
Remove the 3 screws,
and then the wire
fixture.
7
8
Remove the earth/
ground screw.
Remove the 5 screws.
For models with protection
net
Remove the 6 screws.
9
10
Lift up the right side
panel to unfasten the 2
hooks.
Remove the right side
panel.
When reassembling, make
sure to fit the rear hook.
Step
Procedure
Points
Power supply wire
Terminal board
Connecting
wire
Wire fixture
(R22852)
Earth/
ground
screw
(R24112)
(R22854)
Hook
Right side
panel
(R22855)
Hook
(R21317)