![background image](http://html1.mh-extra.com/html/daikin/rkm20qvma/rkm20qvma_service-manual_2459836008.webp)
Electrical Box / PCB
Si001653EA
6
Removal Procedure
2. Remove the electrical
box.
1: black, back
2: white, back
3: red, front
1
Disconnect the 3
connectors from the
terminal board.
2
Disconnect the
connector [S80].
[S80]: four way valve coil
Cooling only models have no
harness for [S80].
3
Disconnect the
connector [S40].
[S40]: overload protector
Step
Procedure
Points
Connector
(R22835)
[S80]
(R22836)
[S40]
(R22837)