1 .3 . Indoor capacity range
Total capacity of indoor units needs to be within the specified range.
<Outdoor unit>
<Total capacity index of indoor unit>
REYQ72TTJU/TYDN
. . . . . . . . . . . . . . . . . . . . .
36-93
REYQ96TTJU/TYDN
. . . . . . . . . . . . . . . . . . . . . 48-124
REYQ120TTJU/TYDN
. . . . . . . . . . . . . . . . . . . . . 60-156
REYQ144TTJU/TYDN
. . . . . . . . . . . . . . . . . . . . . 72-187
REYQ168TTJU/TYDN
. . . . . . . . . . . . . . . . . . . . . 84-218
REYQ192TTJU/TYDN
. . . . . . . . . . . . . . . . . . . . . 96-249
REYQ216TTJU/TYDN
. . . . . . . . . . . . . . . . . . . . . 108-280
REYQ240TTJU/TYDN
. . . . . . . . . . . . . . . . . . . . . 120-312
REYQ264TTJU/TYDN
. . . . . . . . . . . . . . . . . . . . . 132-343
REYQ288TTJU/TYDN
. . . . . . . . . . . . . . . . . . . . . 144-374
REYQ312TTJU/TYDN
. . . . . . . . . . . . . . . . . . . . . 156-405
REYQ336TTJU/TYDN
. . . . . . . . . . . . . . . . . . . . . 168-436
REYQ360TTJU/TYDN
. . . . . . . . . . . . . . . . . . . . . 180-468
REYQ384TTJU/TYDN
. . . . . . . . . . . . . . . . . . . . . 192-499
REYQ408TTJU/TYDN
. . . . . . . . . . . . . . . . . . . . . 204-530
REYQ432TTJU/TYDN
. . . . . . . . . . . . . . . . . . . . . 216-561
REYQ456TTJU/TYDN
. . . . . . . . . . . . . . . . . . . . . 228-592
NOTE
Higher capacity than the above table can be selected, this may affect
heating and cooling capacity. For additional information see technical
engineering data.
1 .4 . Scope of the manual
This manual describes the procedures for handling, installing and
connecting the VRV IV heat recovery outdoor units. This manual has
been prepared to ensure adequate maintenance of the unit, and it will
provide help in case problems occur.
INFORMATION
The installation of the indoor unit(s) is described in the indoor unit
installation manual provided with the indoor units.
2 . Accessories
2 .1 . Accessories supplied with this unit
Confirm the following accessories are included. The storage location
of the accessories is shown in the figure below.
Accessories assy (piping)
Accessories assy (operation
and installation manual)
NOTE
Do not throw away any of the accessories until installation is complete.
They are needed for installation work.
Name
Clamp (1)
Clamp (2)
Clamp (3)
Vinyl tube
Manuals, etc.
Quantity
7 pcs.
1 pc.
1 pc.
5 pcs.
1 pc. each
Shape
(Small)
(Large)
•
Operation Manual
•
Installation Manual
• REQUEST FOR THE
INDICATION label
(Installation records)
Name
Liquid side
accessory
pipe (1)
Liquid side
accessory
pipe (2)
Gas side
accessory
pipe (1)
Gas side
accessory
pipe (2)
Quantity
1 pc.
1 pc.
1 pc.
1 pc.
Shape
168T
72-144T
72,120T
144,168T
96T
72T
96,144,168T
120T
Name
High and low gas
side accessory
pipe (1)
High and low gas
side accessory
pipe (2)
L type
accessory joint
Quantity
1 pc.
1 pc.
2 pcs.
Shape
96-168T
72T
72,96T
120-168T
3 . Overview of unit
3 .1 . Opening the unit
To gain access to the unit, front panels need to be opened as follows:
REYQ72TTJU/TYDN
REYQ96-168TTJU/TYDN
14x
14x
Once the front panel open, the electrical component box can be ac
-
cessed by removing the control box cover as follows.
REYQ72TTJU/TYDN
REYQ96-168TTJU/TYDN
2x
6x
For service purposes, the push buttons on the main printed circuit
board need to be accessed. To access these push buttons, the control
box cover does not need to be opened. See 13. Making field settings
on page 24.
DANGER: ElECTRICAl SHOCk
See Safety considerations on page i.
DANGER: DO NOT TOUCH PIPING AND INTERNAl PARTS
See Safety considerations on page i.