Operation manual
5
HXHD125A7V1B
VRVIII system air conditioner
4PW62583-1 – 11.2010
Explanation of heating operation
It may take longer to reach the set temperature for general heating
operation than for cooling operation.
The following operation is performed in order to prevent the heating
capacity from dropping or cold air from blowing.
Defrost operation
■
In heating operation, freezing of the outdoor unit coil increases.
Heating capability decreases and the system goes into defrost
operation.
■
The indoor unit fan stops and the remote controller displays
.
Hot start
■
In order to prevent cold air from blowing out of an indoor unit at
the start of heating operation, the indoor fan is automatically
stopped. The display of the remote controller shows
.
It may take some time before the fan starts. This is not a
malfunction.
6.2.
Program dry operation
■
The function of this program is to decrease the humidity in your
room with minimal temperature decrease (minimal room
cooling).
■
The micro computer automatically determines temperature and
fan speed (cannot be set by the remote controller).
■
The system does not go into operation if the room temperature
is low (<20°C).
For systems without cool/heat changeover remote control
switch
1
Press the operation mode selector button several times and
select
(program dry operation).
2
Press the on/off button.
The operation lamp lights up and the system starts operating.
3
Press the air flow direction adjust button. (Only for Double-flow,
Multi-flow, Corner, Ceiling-suspended and Wall-mounted.) Refer
to
"6.3. Adjusting the air flow direction" on page 6
for details.
Stopping the system
4
Press the on/off button once again.
The operation lamp goes off and the system stops operating.
For systems with cool/heat changeover remote control switch
1
Select cooling operation mode with the cool/heat changeover
remote control switch.
2
Press the operation mode selector button several times and
select
(program dry operation).
3
Press the on/off button.
The operation lamp lights up and the system starts operating.
4
Press the air flow direction adjust button. (Only for Double-flow,
Multi-flow, Corner, Ceiling-suspended and Wall-mounted.) Refer
to
"6.3. Adjusting the air flow direction" on page 6
for details.
Stopping the system
5
Press the on/off button once again.
The operation lamp goes off and the system stops operating.
INFORMATION
■
The heating capacity drops when the outside
temperature falls. If this happens, use another heating
device together with the unit. (When using together
with appliances that produce open fire, ventilate the
room constantly.)
Do not place appliances that produce open fire in
places exposed to the air flow from the unit or under
the unit.
■
It takes some time to heat up the room from the time
the unit is started since the unit uses a hot-air
circulating system to heat the entire room.
■
If the hot air rises to the ceiling, leaving the area
above the floor cold, we recommend that you use the
circulator (the indoor fan for circulating air). Contact
your dealer for details.
NOTICE
Do not turn off power immediately after the unit stops, but
wait for at least 5 minutes.
NOTICE
Do not turn off power immediately after the unit stops, but
wait for at least 5 minutes.
2+4
1
3
1
1
3+5
2
4