Explanation of heating operation

It may take longer to reach the set temperature for general heating
operation than for cooling operation.

The following operation is performed in order to prevent the heating
capacity from dropping or cold air from blowing.

Defrost operation

In heating operation, freezing of the outdoor unit coil increases.
Heating capability decreases and the system goes into defrost
operation.

The indoor unit fan stops and the remote controller displays

.

Hot start

In order to prevent cold air from blowing out of an indoor unit at
the start of heating operation, the indoor fan is automatically
stopped. The display of the remote controller shows 

.

It may take some time before the fan starts. This is not a
malfunction.

6.2.

Program dry operation

The function of this program is to decrease the humidity in your
room with minimal temperature decrease (minimal room
cooling).

The micro computer automatically determines temperature and
fan speed (cannot be set by the remote controller).

The system does not go into operation if the room temperature
is low (<20°C).

For systems without cool/heat changeover remote control 
switch

1

Press the operation mode selector button several times and
select 

 (program dry operation).

2

Press the on/off button.

The operation lamp lights up and the system starts operating.

3

Press the air flow direction adjust button. (Only for Double-flow,
Multi-flow, Corner, Ceiling-suspended and Wall-mounted.) Refer
to 

"6.3. Adjusting the air flow direction" on page 6

 for details.

Stopping the system

4

Press the on/off button once again.

The operation lamp goes off and the system stops operating.

For systems with cool/heat changeover remote control switch

1

Select cooling operation mode with the cool/heat changeover
remote control switch.

2

Press the operation mode selector button several times and
select 

 (program dry operation).

3

Press the on/off button.

The operation lamp lights up and the system starts operating.

4

Press the air flow direction adjust button. (Only for Double-flow,
Multi-flow, Corner, Ceiling-suspended and Wall-mounted.) Refer
to 

"6.3. Adjusting the air flow direction" on page 6

 for details.

Stopping the system

5

Press the on/off button once again.

The operation lamp goes off and the system stops operating.

INFORMATION

The heating capacity drops when the outside
temperature falls. If this happens, use another heating
device together with the unit. (When using together
with appliances that produce open fire, ventilate the
room constantly.)
Do not place appliances that produce open fire in
places exposed to the air flow from the unit or under
the unit.

It takes some time to heat up the room from the time
the unit is started since the unit uses a hot-air
circulating system to heat the entire room.

If the hot air rises to the ceiling, leaving the area
above the floor cold, we recommend that you use the
circulator (the indoor fan for circulating air). Contact
your dealer for details.

NOTICE

Do not turn off power immediately after the unit stops, but
wait for at least 5 minutes.

NOTICE

Do not turn off power immediately after the unit stops, but
wait for at least 5 minutes.

2+4

1

3

1

1

3+5

2

4

Summary of Contents for REYAQ10P7Y1B

Page 1: ...VRVIII system air conditioner OPERATION MANUAL REYAQ10P7Y1B REYAQ12P7Y1B REYAQ14P7Y1B REYAQ16P7Y1B system air conditioner ...

Page 2: ...l specified for a certain product or application explaining how to install configure and maintain it Operation manual Instruction manual specified for a certain product or application explaining how to operate it Maintenance instructions Instruction manual specified for a certain product or application which explains if relevant how to install configure operate and or maintain the product or applicatio...

Page 3: ...ful gas Turn off any combustible heating devices ventilate the room and contact the dealer where you purchased the unit Do not use the air conditioner until a service person confirms that the portion where the refrigerant leaks is repaired Improper installation or attachment of equipment or accessories could result in electric shock short circuit leaks fire or other damage to the equipment Be sure t...

Page 4: ...ct sunlight The LCD display may get discolored failing to display the data Do not wipe the controller operation panel with benzine thinner chemical dustcloth etc The panel may get discolored or the coating peeled off If it is heavily dirty soak a cloth in water diluted neutral detergent squeeze it well and wipe the panel clean Wipe it with another dry cloth Do not operate the air conditioner when ...

Page 5: ...nd select the operation mode of your choice Cooling operation Heating operation Automatic operation Fan only operation 2 Press the on off button The operation lamp lights up and the system starts operating For systems with cool heat changeover remote control switch Overview of the changeover remote control switch 1 FAN ONLY AIR CONDITIONING SELECTOR SWITCH Set the switch to for fan only operation ...

Page 6: ... Wall mounted Refer to 6 3 Adjusting the air flow direction on page 6 for details Stopping the system 4 Press the on off button once again The operation lamp goes off and the system stops operating For systems with cool heat changeover remote control switch 1 Select cooling operation mode with the cool heat changeover remote control switch 2 Press the operation mode selector button several times an...

Page 7: ... The unit is individually operated 7 ENERGY SAVING AND OPTIMUM OPERATION Observe the following precautions to ensure the system operates properly Adjust the air outlet properly and avoid direct air flow to room inhabitants Adjust the room temperature properly for a comfortable environment Avoid excessive heating or cooling Prevent direct sunlight from entering a room during cooling operation by usi...

Page 8: ...ter the power supply is turned on Wait one minute until the micro computer is prepared for operation Symptom 2 Cool Heat cannot be changed over When the display shows change over under centralized control it shows that this is a slave remote controller When the cool heat changeover remote control switch is installed and the display shows change over under centralized control This is because cool h...

Page 9: ...tom 9 Dust comes out of the unit When the unit is used for the first time in a long time This is because dust has gotten into the unit Symptom 10 The units can give off odours The unit can absorb the smell of rooms furniture cigarettes etc and then emit it again Symptom 11 The outdoor unit fan does not spin During operation The speed of the fan is controlled in order to optimize product operation S...

Page 10: ...nditioner are necessary within the warranty period contact your dealer and keep the warranty card at hand 11 1 After sales service Recommendations for maintenance and inspection Since dust collects when using the unit for several years performance of the unit will deteriorate to some extent As taking apart and cleaning interiors of units requires technical expertise and in order to ensure the best...

Page 11: ...ype R410A GWP 1 value 1975 1 GWP global warming potential Periodical inspections for refrigerant leaks may be required depending on European or local legislation Please contact your local dealer for more information NOTICE 1 Table 1 indicates main components Refer to your maintenance and inspection contract for more details 2 Table 1 indicates recommended intervals of maintenance cycles However in...

Page 12: ...4PW62583 1 11 2010 Copyright 2011 Daikin ...

Reviews: