background image

HXHD125A7V1B

VRVIII system air conditioner

4PW62583-1 – 11.2010

Operation manual

2

Accessories:

Equipment which is delivered with the unit and which needs to be
installed according to instructions in the documentation.

Optional equipment: 

Equipment which can optionally be combined to the products as per
the subject of this manual.

Field supply:

Equipment which needs to be installed according to instructions in
this manual, but which are not supplied by Daikin.

2.

I

NTRODUCTION

2.1.

General information

The unit is the indoor part of the air to water REYAQ heat pump and
used for heating/cooling applications.

Refer to the installation manual for the list of options.

Do not place objects in direct proximity of the outdoor
unit and do not let leaves and other debris accumulate
around the unit.
Leaves are a hotbed for small animals which can enter
the unit. Once in the unit, such animals can cause
malfunctions, smoke or fire when making contact with
electrical parts.

Ask your dealer for improvement, repair, and
maintenance. 
Incomplete improvement, repair, and maintenance
may result in a water leakage, electric shock and fire.

Do not insert fingers, rods or other objects into the air
inlet or outlet. When the fan is rotating at high speed, it
will cause injury.

Never let the indoor unit or the remote controller get
wet.
It may cause an electric shock or a fire.

Never use a flammable spray such as hair spray,
lacquer or paint near the unit. 
It may cause a fire.

Never touch the air outlet or the horizontal blades
while the swing flap is in operation.
Fingers may become caught or the unit may break
down.

Never replace a fuse with a fuse of a wrong ampere
ratings or other wires when a fuse blows out.
Use of wire or copper wire may cause the unit to break
down or cause a fire.

To prevent refrigerant leak, contact your dealer.
When the system is installed and runs in a small room,
it is required to keep the concentration of the
refrigerant, if by any chance coming out, below the
limit. Otherwise, oxygen in the room may be affected,
resulting in a serious accident.

The refrigerant in the air conditioner is safe and
normally does not leak. If the refrigerant leaks in the
room, contact with a fire of a burner, a heater or a
cooker may result in a harmful gas.

Turn off any combustible heating devices, ventilate the
room and contact the dealer where you purchased the
unit.
Do not use the air conditioner until a service person
confirms that the portion where the refrigerant leaks is
repaired.

Improper installation or attachment of equipment or
accessories could result in electric shock, short-
circuit, leaks, fire or other damage to the equipment.
Be sure to use only accessories made by Daikin which
are specifically designed for use with the equipment
and have them installed by a professional.

Ask your dealer to move and reinstall the air
conditioner.
Incomplete installation may result in a water leakage,
electric shock, and fire.

Do not place a flammable spray bottle near the air
conditioner and do not use sprays.
Doing so may result in a fire.

Before cleaning, be sure to stop the operation, turn
the breaker off or pull out the supply cord.
Otherwise, an electric shock and injury may result.

Do not operate the air conditioner with a wet hand.
An electric shock may result.

Do not place appliances which produce open fire in
places exposed to the air flow from the unit or under
the indoor unit. It may cause incomplete combustion
or deformation of the unit due to the heat.

Do not wash the air conditioner with water.
Electric shock or fire may result.

Do not install the air conditioner at any place where
flammable gas may leak out.
If the gas leaks out and stays around the air
conditioner, a fire may break out.

In order to avoid electric shock or fire, make sure that
an earth leak detector is installed.

Be sure the air conditioner is electrically earthed.
In order to avoid electric shock, make sure that the
unit is grounded and that the earth wire is not
connected to gas or water pipe, lightning conductor or
telephone earth wire.

Do not place a flower vase or anything containing
water on the unit.
Water may enter the unit, causing an electric shock or
fire.

Avoid placing the controller in a spot which can be
splashed with water.
Water entering the machine may cause an electric
leak or may damage the internal electronic parts.

NOTICE

An HXHD125 indoor unit can only be connected to an
REYAQ outdoor unit.

INFORMATION

This manual does not apply for the HXHD125 indoor unit.
Refer to the installation and operation manual of the
HXHD125 indoor unit for this information.

WARNING

If you detect any abnormality such as smell of fire,
turn off the power supply and call your dealer for
instructions.

Summary of Contents for REYAQ10P7Y1B

Page 1: ...VRVIII system air conditioner OPERATION MANUAL REYAQ10P7Y1B REYAQ12P7Y1B REYAQ14P7Y1B REYAQ16P7Y1B system air conditioner ...

Page 2: ...l specified for a certain product or application explaining how to install configure and maintain it Operation manual Instruction manual specified for a certain product or application explaining how to operate it Maintenance instructions Instruction manual specified for a certain product or application which explains if relevant how to install configure operate and or maintain the product or applicatio...

Page 3: ...ful gas Turn off any combustible heating devices ventilate the room and contact the dealer where you purchased the unit Do not use the air conditioner until a service person confirms that the portion where the refrigerant leaks is repaired Improper installation or attachment of equipment or accessories could result in electric shock short circuit leaks fire or other damage to the equipment Be sure t...

Page 4: ...ct sunlight The LCD display may get discolored failing to display the data Do not wipe the controller operation panel with benzine thinner chemical dustcloth etc The panel may get discolored or the coating peeled off If it is heavily dirty soak a cloth in water diluted neutral detergent squeeze it well and wipe the panel clean Wipe it with another dry cloth Do not operate the air conditioner when ...

Page 5: ...nd select the operation mode of your choice Cooling operation Heating operation Automatic operation Fan only operation 2 Press the on off button The operation lamp lights up and the system starts operating For systems with cool heat changeover remote control switch Overview of the changeover remote control switch 1 FAN ONLY AIR CONDITIONING SELECTOR SWITCH Set the switch to for fan only operation ...

Page 6: ... Wall mounted Refer to 6 3 Adjusting the air flow direction on page 6 for details Stopping the system 4 Press the on off button once again The operation lamp goes off and the system stops operating For systems with cool heat changeover remote control switch 1 Select cooling operation mode with the cool heat changeover remote control switch 2 Press the operation mode selector button several times an...

Page 7: ... The unit is individually operated 7 ENERGY SAVING AND OPTIMUM OPERATION Observe the following precautions to ensure the system operates properly Adjust the air outlet properly and avoid direct air flow to room inhabitants Adjust the room temperature properly for a comfortable environment Avoid excessive heating or cooling Prevent direct sunlight from entering a room during cooling operation by usi...

Page 8: ...ter the power supply is turned on Wait one minute until the micro computer is prepared for operation Symptom 2 Cool Heat cannot be changed over When the display shows change over under centralized control it shows that this is a slave remote controller When the cool heat changeover remote control switch is installed and the display shows change over under centralized control This is because cool h...

Page 9: ...tom 9 Dust comes out of the unit When the unit is used for the first time in a long time This is because dust has gotten into the unit Symptom 10 The units can give off odours The unit can absorb the smell of rooms furniture cigarettes etc and then emit it again Symptom 11 The outdoor unit fan does not spin During operation The speed of the fan is controlled in order to optimize product operation S...

Page 10: ...nditioner are necessary within the warranty period contact your dealer and keep the warranty card at hand 11 1 After sales service Recommendations for maintenance and inspection Since dust collects when using the unit for several years performance of the unit will deteriorate to some extent As taking apart and cleaning interiors of units requires technical expertise and in order to ensure the best...

Page 11: ...ype R410A GWP 1 value 1975 1 GWP global warming potential Periodical inspections for refrigerant leaks may be required depending on European or local legislation Please contact your local dealer for more information NOTICE 1 Table 1 indicates main components Refer to your maintenance and inspection contract for more details 2 Table 1 indicates recommended intervals of maintenance cycles However in...

Page 12: ...4PW62583 1 11 2010 Copyright 2011 Daikin ...