background image

Operation manual

1

HXHD125A7V1B

VRVIII system air conditioner

4PW62583-1 – 11.2010

C

ONTENTS

Page

1. Definitions.................................................................................. 1

1.1. Meaning of warnings and symbols .............................................. 1
1.2. Meaning of used terms ................................................................ 1

2. Introduction................................................................................ 2

2.1. General information ..................................................................... 2

3. What to do before operation ...................................................... 3

4. Remote controller ...................................................................... 3

5. Operation range......................................................................... 3

6. Operation procedure.................................................................. 4

6.1. Cooling, heating, fan only, and automatic operation .................... 4
6.2. Program dry operation ................................................................. 5
6.3. Adjusting the air flow direction ..................................................... 6
6.4. Setting the master remote controller............................................ 6
6.5. Precautions for group control system or two remote controller 

control system.............................................................................. 6

7. Energy saving and optimum operation ...................................... 6

8. Maintenance .............................................................................. 7

8.1. Maintenance after a long stop period .......................................... 7
8.2. Maintenance before a long stop period ....................................... 7

9. Following symptoms are not air conditioner troubles................. 7

10. Troubleshooting ......................................................................... 8

11. After-sales service and warranty ............................................... 9

11.1. After-sales service ....................................................................... 9
11.2. Shortening of "maintenance cycle" and "replacement cycle" 

needs to be considered in following situations........................... 10

12. Important information regarding the refrigerant used .............. 10

Thank you for purchasing this Daikin air conditioner.

The original instructions are written in English. All other languages
are translations of the original instructions.

This appliance is not intended for use by persons, including children,
with reduced physical, sensory or mental capabilities, or lack of
experience and knowledge, unless they have been given supervision
or instruction concerning use of the appliance by a person
responsible for their safety.
Children shall be supervised to ensure that they do not play with the
appliance.

1. D

EFINITIONS

1.1.

Meaning of warnings and symbols

Warnings in this manual are classified according to their severity and
probability of occurrence.

Some types of danger are represented by special symbols:

1.2.

Meaning of used terms

Installation manual:

Instruction manual specified for a certain product or application,
explaining how to install, configure and maintain it.

Operation manual:

Instruction manual specified for a certain product or application,
explaining how to operate it.

Maintenance instructions:

Instruction manual specified for a certain product or application,
which explains (if relevant) how to install, configure, operate and/or
maintain the product or application.

Dealer:

Sales distributor for products as per the subject of this manual.

Installer:

Technical skilled person who is qualified to install products as per the
subject of this manual.

User:

Person who is owner of the product and/or operates the product.

Service company:

Qualified company which can perform or coordinate the required
service to the unit.

Applicable legislation:

All international, European, national and local directives, laws,
regulations and/or codes which are relevant and applicable for a
certain product or domain.

REYAQ10P7Y1B

REYAQ14P7Y1B

REYAQ12P7Y1B

REYAQ16P7Y1B

VRVIII system air conditioner

Operation manual

CAREFULLY READ THESE INSTRUCTIONS BEFORE
OPERATING THE UNIT. THEY WILL TELL YOU HOW TO
USE THE UNIT PROPERLY. KEEP THIS MANUAL IN A
HANDY PLACE FOR FUTURE REFERENCE.

WARNING

This unit contains electrical and hot parts.

Before operating the unit, be sure the installation has
been carried out correctly by an installer.
If you feel unsure about operation, contact your
installer for advice and information.

DANGER

Indicates an imminently hazardous situation which, if not
avoided, will result in death or serious injury.

WARNING

Indicates a potentially hazardous situation which, if not
avoided, could result in death or serious injury.

CAUTION

Indicates a potentially hazardous situation which, if not
avoided, may result in minor or moderate injury. It may also
be used to alert against unsafe practices.

NOTICE

Indicates situations that may result in equipment or
property-damage accidents only.

INFORMATION

This symbol identifies useful tips or additional information.

Electric current.

Danger of burning and scalding.

Summary of Contents for REYAQ10P7Y1B

Page 1: ...VRVIII system air conditioner OPERATION MANUAL REYAQ10P7Y1B REYAQ12P7Y1B REYAQ14P7Y1B REYAQ16P7Y1B system air conditioner ...

Page 2: ...l specified for a certain product or application explaining how to install configure and maintain it Operation manual Instruction manual specified for a certain product or application explaining how to operate it Maintenance instructions Instruction manual specified for a certain product or application which explains if relevant how to install configure operate and or maintain the product or applicatio...

Page 3: ...ful gas Turn off any combustible heating devices ventilate the room and contact the dealer where you purchased the unit Do not use the air conditioner until a service person confirms that the portion where the refrigerant leaks is repaired Improper installation or attachment of equipment or accessories could result in electric shock short circuit leaks fire or other damage to the equipment Be sure t...

Page 4: ...ct sunlight The LCD display may get discolored failing to display the data Do not wipe the controller operation panel with benzine thinner chemical dustcloth etc The panel may get discolored or the coating peeled off If it is heavily dirty soak a cloth in water diluted neutral detergent squeeze it well and wipe the panel clean Wipe it with another dry cloth Do not operate the air conditioner when ...

Page 5: ...nd select the operation mode of your choice Cooling operation Heating operation Automatic operation Fan only operation 2 Press the on off button The operation lamp lights up and the system starts operating For systems with cool heat changeover remote control switch Overview of the changeover remote control switch 1 FAN ONLY AIR CONDITIONING SELECTOR SWITCH Set the switch to for fan only operation ...

Page 6: ... Wall mounted Refer to 6 3 Adjusting the air flow direction on page 6 for details Stopping the system 4 Press the on off button once again The operation lamp goes off and the system stops operating For systems with cool heat changeover remote control switch 1 Select cooling operation mode with the cool heat changeover remote control switch 2 Press the operation mode selector button several times an...

Page 7: ... The unit is individually operated 7 ENERGY SAVING AND OPTIMUM OPERATION Observe the following precautions to ensure the system operates properly Adjust the air outlet properly and avoid direct air flow to room inhabitants Adjust the room temperature properly for a comfortable environment Avoid excessive heating or cooling Prevent direct sunlight from entering a room during cooling operation by usi...

Page 8: ...ter the power supply is turned on Wait one minute until the micro computer is prepared for operation Symptom 2 Cool Heat cannot be changed over When the display shows change over under centralized control it shows that this is a slave remote controller When the cool heat changeover remote control switch is installed and the display shows change over under centralized control This is because cool h...

Page 9: ...tom 9 Dust comes out of the unit When the unit is used for the first time in a long time This is because dust has gotten into the unit Symptom 10 The units can give off odours The unit can absorb the smell of rooms furniture cigarettes etc and then emit it again Symptom 11 The outdoor unit fan does not spin During operation The speed of the fan is controlled in order to optimize product operation S...

Page 10: ...nditioner are necessary within the warranty period contact your dealer and keep the warranty card at hand 11 1 After sales service Recommendations for maintenance and inspection Since dust collects when using the unit for several years performance of the unit will deteriorate to some extent As taking apart and cleaning interiors of units requires technical expertise and in order to ensure the best...

Page 11: ...ype R410A GWP 1 value 1975 1 GWP global warming potential Periodical inspections for refrigerant leaks may be required depending on European or local legislation Please contact your local dealer for more information NOTICE 1 Table 1 indicates main components Refer to your maintenance and inspection contract for more details 2 Table 1 indicates recommended intervals of maintenance cycles However in...

Page 12: ...4PW62583 1 11 2010 Copyright 2011 Daikin ...

Reviews: