background image

2

We recommend that you read this instruction manual carefully 
before use to gain full advantage of the functions of the air 
conditioner and to avoid malfunction due to mishandling. This 
air conditioner comes under the term “appliances not accessible to 
the general public”.

!

The precautions described below are WARNING and CAUTION. These are very important precautions 
concerning safety. Be sure to observe all of them without fail.

WARNING ......

These are the matters with possibilities leading to serious consequences such as death or serious injury due 
to erroneous handling.

CAUTION .......

These are the matters with possibilities leading to injury or material damage due to erroneous handling 
including probabilities leading to serious consequences in some cases.

!

After reading, keep this manual at a place where any user can read at any time. Furthermore, make 
certain that this operation manual is handed to a new user if required.

SAFETY CONSIDERATIONS

!

Avoid prolonged exposure of your body to direct streams 
of cold air.
Your physical condition may deteriorate.

!

If the air conditioner is in abnormal conditions (smell of 
something burning, etc.), switch the air conditioner off at 
the main switch, and contact the dealer where you 
purchased the air conditioner.
Continued operation under such circumstances may result 
in a failure, electric shock or fire.

!

Only use a qualified installer for installation of the air
conditioner.
Incorrect installation performed may result in a water
leakage, electric shock or fire.

!

Ask your dealer for improvement, repair, and maintenance.
Incorrect improvement, repair, and maintenance may result 
in a water leakage, electric shock or fire.

!

Never remove any fixed covers on the indoor or outdoor 
unit.
Removal of the covers may expose fast moving fan blades 
or electrical components operating at a hazardous voltage. 
Contact with the blades or high voltage componenets may
result in injury or electric shock.

!

For refrigerant leakage, consult your dealer.
If the air conditioner is to be installed in a small room, 
it is necessary to take proper measures so that the amount 
of any leaked refrigerant does not exceed the limiting 
concentration. If the refrigerant leaks exceeding the level of
limiting concentration, an oxygen deficiency accident may 
happen.

!

For installation of separately sold component parts, 
ask a specialist only.
Be sure to use separately sold component parts designated 
by Daikin. Incomplete installation performed by yourself 
may result in a water leakage, electric shock or fire.

!

Ask your dealer to move and reinstall the air conditioner.
Incomplete installation may result in a water leakage, 
electric shock or fire.

!

Never insert any objects into the openings in the indoor or 
outdoor unit.
This may damage the product or result in injury to the 
person inserting the object.

WARNING

!

Do not use the air conditioner for other purposes.
Do not use the air conditioner for special applications such 
as the storage of foods, animals and plants, precision 
machines, and art objects. Deterioration of quality may 
result.

!

When the air conditioner is used in combination with 
burners or heaters, ensure sufficient ventilation.
Insufficient ventilation may result in an oxygen deficiency 
accident.

!

Reguarly check the quality of the foundation blocks.
If they are left in a damaged condition, the unit may fall and 
result in injury.

!

Do not place or use a flammable spray can near the air
conditioner.
Doing so may result in a fire.

!

To clean the air conditioner, stop operation and switch the 
power off at the main switch.
Otherwise, an electric shock and injury may result.

!

Do not expose the indoor unit or remote controller to rain 
or moisture.
Water or other fluids on the electrical components may 
result in fire or electric shock.

!

Always replace any blown fuse with a fuse of the same 
specification.
The use of the wrong type fuse may allow the electrical 
wiring to overheat and catch on fire. If the correct type of
fuse continues to blow contact your installer or electrician.

!

Do not place a burner or heater at a place directly 
exposed to the wind from the air conditioner.
Incomplete combustion of the burner or heater may result.

!

This electrical appliance is not intended for use by young 
children or infirm persons without supervision.
Young children should be supervised to ensure that they do 
not play with the outdoor unit.

!

Do not expose animals and plants directly to the air stream 
from the outdoor unit.
Adverse influence to animals and plants may result.

!

Do not wash the air conditioner with water.
An electric shock may result.

!

Do not install the air conditioner at any place where 
flammable gas may be present.
If the gas leaks out and stays around the air conditioner, a 
fire may break out.

!

Execute complete drain piping for perfect drainage.
Incomplete piping may result in a water leakage.

!

Never operate the air conditioner without the return air 
filter(s) in place.
Operating the unit without the filter(s) will allow dust to 
enter the indoor unit and build up on the heat exchanger 
coil and fan motor. This will cause a malfunction of the unit 
which will not be covered by Warranty.

CAUTION

Summary of Contents for Remote Controller BRC1C61

Page 1: ...system available Before operating the air conditioner please read this operating manual carefully It will advise you on how to operate the unit correctly understand the air conditioner s advanced fea...

Page 2: ...may result in a water leakage electric shock or fire Ask your dealer to move and reinstall the air conditioner Incomplete installation may result in a water leakage electric shock or fire Never inser...

Page 3: ...NERAL OPERATION 6 ADVANCED FEATURES 8 OPTIMUM OPERATION 8 SELF DIAGNOSIS 9 NOT MALFUNCTION OF THE AIR CONDITONER 9 TROUBLE SHOOTING 10 USER MAINTENANCE 11 Fig 1 4 Fig 2 6 Fig 3 4 7 Fig 5 9 MAIN SWITCH...

Page 4: ...uch as plants boxes fences etc may result in declined performance and increased running noises If abnormal noises occur in use consult your dealer Ensure the drain piping from the indoor unit is free...

Page 5: ...utton to reset the CLEAN FILTER INDICATOR after you have inspected cleaned the indoor return air filter FAN SPEED DISPLAY FAN SPEED SELECTOR BUTTON This display indicates the selected fan speed ie hig...

Page 6: ...an speed to extra low or low when the desired room temperature is reached and the compressor cycles off This is to avoid cold draughts 5 To turn the air conditioner off simply press the ON OFF BUTTON...

Page 7: ...he FAN MODE only the indoor fan is energised The outdoor unit will not operate and therefore heating or cooling will not be provided This mode is useful for circulating the air within the building 1 P...

Page 8: ...ntrol may be added to the system to allow setting and control of the unit at two different locations This is particularly useful in two storey applications where one controller can be installed upstai...

Page 9: ...e one of its safety devices has actuated to prevent the system from being overloaded The system will turn on again automatically after the passage of three minutes In the unlikely event that a fault d...

Page 10: ...om unit Measure Stop the operation If the display INSPECTION UNIT No and the OPERATION lamp flash 2 and the MALFUNCTION CODE appears TEST C H UNIT No INSPECTION display INDOOR UNIT No in which a malfu...

Page 11: ...ecommended NOTE The air filter s and the suction grille s are supplied by your dealer Ask your DAIKIN dealer how to clean them HOW TO CLEAN AIR OUTLET GRILLE Clean with soft cloth When it is difficult...

Page 12: ...0 787 266 www daikin com au DAIKIN I INDUSTRIES L LTD Head office Umeda Centre Building 4 12 Nakazaki Nishi 2 chome Kita ku Osaka 530 8323 Japan Tokyo office Shinjuku Sumitomo Building 6 1 Nishi Shinj...