The system does not restart immediately when
the TEMPERATURE SETTING button is 
returned to its former position after pushing.
If the OPERATION lamp lights, the system is in its 
normal operating condition.
It may not restart immediately because one of its 
safety devices has actuated to prevent the system 
from being overloaded. The system will turn on 
again automatically after the passage of three 
minutes.

!

The system does not start when the display 
shows “                 “ (UNDER CENTRALIZED 
CONTROL) and it flashes for few seconds after 
pressing an operation button.
This is because the system is under centralized 
control. Flashes on the display indicates that the 
system cannot be controlled by the remote 
controller.

!

The system does not start immediately after the
power supply is turned on.
Wait one minute until the micro computer is 
prepared for operation.

!

The outdoor unit is stopped.
This is because the room temperature has 
reached the set temperature. The indoor unit 
switches to fan operation.

WHITE MIST COMES OUT OF THE OUTDOOR UNIT

!

When the system reverts to HEATING 
OPERATION after DEFROST OPERATION.
Moisture generated by DEFROST becomes steam
and is discharged.

The following symptoms do not indicate that the air
conditioner has malfunctioned.

THE SYSTEM DOES NOT OPERATE

!

The system does not restart immediately after
the ON / OFF button is pressed.
If the OPERATION lamp lights, the system is in its 
normal operating condition.
It may not restart immediately because one of its 
safety devices has actuated to prevent the system 
from being overloaded. The system will turn on 
again automatically after the passage of three 
minutes.

In the unlikely event that a fault develops with the air 
conditioner the microprocessor in the indoor and 
outdoor units will diagnose the fault (where possible),
display a unique fault code on the remote controller
(see below) and flash the OPERATION INDICATOR (2)
on and off. If this occurs take a note of the fault code
(eg. A1) and contact your installer. This code will 
indicate to the installer / repairer what the problem
may be.

TEST

C

H

UNIT  No.

INSPECTION
display

INDOOR UNIT
No. in which a 
malfunction occurs

MALFUNCTION CODE

2

Fig. 5

OPERATION RANGE
If the temperature or the humidity is outside the 
following conditions, safety devices may work and the 
air conditioner may not operate.

Cooling

Indoor

DB

19 to 35

WB

12 to 25

(Humidity 80% or below)

Outdoor

DB

-5 to 46

Heating

Indoor

DB

10 to 27

Outdoor

DB

-9 to 21

WB

-10 to 15

Temperature (

o

C)

-

-

Temperature (

o

C)

DB: Dry bulb temperature
WB: Wet bulb temperature

15.10 Self Diagnosis

15.11 Not Malfunction of the Air 

Condtioner

!

Turn off the main power supply switch when not 
using for long periods of time. Electricity is 
consumed as long as the switch is on. Turn off the 
main power supply switch in order to save energy. 
Turn on the main power supply switch 6 hours 
before restarting operation in order to ensure 
smooth operation. (Refer to MAINTENANCE)

!

Ventilate the room regularly.
Using the unit for long periods of time requires
regular ventilation of the room.

!

When the display shows “        “ (TIME TO CLEAN
THE AIR FILTER), clean the filter(s). (Refer to 
MAINTENANCE)

Summary of Contents for Remote Controller BRC1C61

Page 1: ...system available Before operating the air conditioner please read this operating manual carefully It will advise you on how to operate the unit correctly understand the air conditioner s advanced fea...

Page 2: ...may result in a water leakage electric shock or fire Ask your dealer to move and reinstall the air conditioner Incomplete installation may result in a water leakage electric shock or fire Never inser...

Page 3: ...NERAL OPERATION 6 ADVANCED FEATURES 8 OPTIMUM OPERATION 8 SELF DIAGNOSIS 9 NOT MALFUNCTION OF THE AIR CONDITONER 9 TROUBLE SHOOTING 10 USER MAINTENANCE 11 Fig 1 4 Fig 2 6 Fig 3 4 7 Fig 5 9 MAIN SWITCH...

Page 4: ...uch as plants boxes fences etc may result in declined performance and increased running noises If abnormal noises occur in use consult your dealer Ensure the drain piping from the indoor unit is free...

Page 5: ...utton to reset the CLEAN FILTER INDICATOR after you have inspected cleaned the indoor return air filter FAN SPEED DISPLAY FAN SPEED SELECTOR BUTTON This display indicates the selected fan speed ie hig...

Page 6: ...an speed to extra low or low when the desired room temperature is reached and the compressor cycles off This is to avoid cold draughts 5 To turn the air conditioner off simply press the ON OFF BUTTON...

Page 7: ...he FAN MODE only the indoor fan is energised The outdoor unit will not operate and therefore heating or cooling will not be provided This mode is useful for circulating the air within the building 1 P...

Page 8: ...ntrol may be added to the system to allow setting and control of the unit at two different locations This is particularly useful in two storey applications where one controller can be installed upstai...

Page 9: ...e one of its safety devices has actuated to prevent the system from being overloaded The system will turn on again automatically after the passage of three minutes In the unlikely event that a fault d...

Page 10: ...om unit Measure Stop the operation If the display INSPECTION UNIT No and the OPERATION lamp flash 2 and the MALFUNCTION CODE appears TEST C H UNIT No INSPECTION display INDOOR UNIT No in which a malfu...

Page 11: ...ecommended NOTE The air filter s and the suction grille s are supplied by your dealer Ask your DAIKIN dealer how to clean them HOW TO CLEAN AIR OUTLET GRILLE Clean with soft cloth When it is difficult...

Page 12: ...0 787 266 www daikin com au DAIKIN I INDUSTRIES L LTD Head office Umeda Centre Building 4 12 Nakazaki Nishi 2 chome Kita ku Osaka 530 8323 Japan Tokyo office Shinjuku Sumitomo Building 6 1 Nishi Shinj...

Reviews: