![background image](http://html1.mh-extra.com/html/daikin/r100luy1/r100luy1_service-manual_2460286008.webp)
Procedure to Remove Thermistor
Si241312
6
Removal Procedure
5. Procedure to Remove Thermistor
Procedure
Warning
Be sure to wait for 10 minutes or more after turning off all power
supplies before disassembling work.
Step
Procedure
Points
Removing top panel, front
panel and side panel
according to the
“Procedure to Remove
Outside Panels”.
1
Pick up and pull out the
mounting spring to
remove the discharge
pipe thermistor.
2
To remove the heat
exchanger thermistor,
pull the locking piece
frontward.
3
To remove the outdoor
air thermistor, draw out
frontward and slide it
rightward.
Outdoor air thermistor
Heat exchanger thermistor
Discharge pipe thermistor
(Inside of muffler)
For R71,100LU
and RY125~140LU
Discharge pipe thermistor
(Side of discharge pipe)
For RY71,100LU
and R125~140LU