![background image](http://html1.mh-extra.com/html/daikin/r100luy1/r100luy1_service-manual_2460286007.webp)
Si241312
Procedure to Remove PCB Assy
Removal Procedure
5
4. Procedure to Remove PCB Assy
Procedure
Warning
Be sure to wait for 10 minutes or more after turning off all power
supplies before disassembling work.
Step
Procedure
Points
Removing top panel, front
panel and side panel
according to the
“Procedure to Remove
Outside Panels”.
1
Spread the lower parts
of hooks (3 locations) to
remove the resin cover.
2
Disconnect all
connectors on the PCB.
3
Disconnect 1 screw to
remove the PCB assy.
Claws
Resin cover
Screw
(1 piece)
Glass tube fuse
PCB assy
O
F
F
1
EMG.
DS1
HAP
OFF
HEA
T
J1
ON
COOL
2
3
4
Dip switch 1 (DS 1)
BS button
HAP Service Monitor LED
Jumper wire
FORCED
DEF,
PUMP