60
Diagnostics
General diagnostics
The machine's electrical system includes quality electromechanical components and is therefore ex-
tremely durable and reliable over time.
Should there be any malfunctions due to malfunctions of electrical components it will be necessary to
act as follows:
• Check the fuses of the power supply for the control circuits and if necessary replace them with fuses
having the same specifications.
• Check if the thermal protection switch for the motor has been triggered or if its fuses have blown.
If this has occurred, it may be caused by:
• Motor overload due to mechanical problems. They need to be solved.
• Incorrect supply voltage. Verify the protection trip threshold.
• Malfunction and/or short circuits in the motor. Identify and replace the failed component.
Electrical maintenance
The machine does not require routine maintenance repairs.
Do not modify the machine for any reason and do not add other devices.
The manufacturer is not liable for resulting malfunctions and problems.
Further clarification is available by contacting the manufacturer's Customer Service.
Summary of Contents for Modular Rotary
Page 15: ...15 Notes...
Page 28: ...28 Notes...
Page 33: ...33 VDI 6022 6...
Page 34: ...34 1 x TE8x35 1 x 8 5 1 x M8 2 x TE8x35 2 x 8 5 2 x M8 7...
Page 43: ...43 3 4 5 x 1 100mm 100mm 250mm 250mm 250mm 10 100mm 5mm...
Page 44: ...44 6 7 NO OK...
Page 45: ...45 H2O SOAP 8...
Page 46: ...46 9...
Page 47: ...47 Notes...
Page 62: ...62 Repair log DATE SERVICE TYPE TIME REQUIRED SIGNATURE...