14
|
About the units and options
Installer and user reference guide
41
LRYELRNUN5A7Y1
CO₂ Conveni-Pack outdoor unit
4P605460-1 – 2020.08
14 About the units and options
In this chapter
14.1 Identification
NOTICE
When installing or servicing several units at the same time, make sure NOT to switch
the service panels between different models.
14.1.1 Identification label: Outdoor unit
Location
a
b
a
Outdoor unit
b
Capacity up unit
Model identification
Outdoor unit: LR YE N 10 A7 Y1
Code
Explanation
Outdoor unit: LR YE N 10 A7 Y1:
LR
Product category:
▪
L: Low temperature air conditioner
▪
R: Outdoor unit
YE
He economizer
N
Refrigerant: R744 (CO
2
)
10
Capacity indication in HP
A7
Major design category: European design
Y1
power supply (3~ / 50 Hz / 380~415 V)