![background image](http://html.mh-extra.com/html/daikin/fxuq100aveb/fxuq100aveb_installation-manual_2460207019.webp)
English
18
9.
MOUNTING CORNER COVER · SUC-
TION GRILLE
For test operation without the corner cover, first refer to
“10. FIELD SETTING AND TEST OPERATION”
•
For backward and rightward piping outlet, cut the corner
cover as shown in
Fig. 45
and remove it.
(When cutting, give caution and mount on the indoor unit so
that the parts for the corner cover may not fall off.)
•
Attach the corner cover to the indoor unit.
Then, fix the corner cover with the attached screws (14) while
pressing the corner cover so that the end of the corner cover
and the end of the indoor unit contact together.
(Refer to Fig. 46)
•
After attaching the suction grille in opposite order mentioned
in the clause “
4. PREPARATION BEFORE INSTALLATION -
(3)
”
(Refer to Fig. 47-
(1)
)
, hook the strap (a) for preventing
the suction grille from falling.
(Refer to Fig. 47-
(2)
)
•
Hook the strap (b) for preventing the suction grille from fall-
ing.
(Refer to Fig. 47-
(3)
)
10. FIELD SETTING AND TEST OPERATION
Refer to also the installation manual attached to the out-
door unit.
CAUTION
Before carrying out field setting, check the items mentioned in
the clause 2 “
1. Items to be checked after the installation
work is completed
” on page 3.
•
Check if all the installation and piping works for the air condi-
tioner are completed.
•
Check if the control box lids of the air conditioner are closed.
Fig. 45
Piping penetrating place
Piping penetrating place
Cut with saw blade.
Cut with a saw blade.
For backward piping outlet
For rightward piping outlet
Corner cover
Corner cover
Give caution so
that it may not fall
off.
Give caution so
that it may not fall
off.
Fig. 46
Corner cover
Screw (14) (accessory)
Screw (14)
(accessory)
Corner cover
Screw (14) (accessory)
Corner cover
Indoor unit
Screw (14) (accessory)
Corner cover
Have the end of
the corner cover
and the end of
the indoor unit
contact together.
(all 4 corners)
Have the end of the corner cover
and the end of the indoor unit
contact together. (all 4 corners)
Fig. 47
(1)
(2)
(2)
(3)
(3)
Hook the strap
Strap (b) for
preventing
the suction grille
from falling
Strap (a) for
preventing
the suction grille
from falling
(3 places)
(1 place)
Corner cover
(Piping section)
Hook the strap on the nearer one