background image

INSTALLATION AND OPERATION MANUAL

FXSQ20M7V1B
FXSQ25M7V1B
FXSQ32M7V1B
FXSQ40M7V1B
FXSQ50M7V1B
FXSQ63M7V1B
FXSQ80M7V1B
FXSQ100M7V1B
FXSQ125M7V1B

System air conditioner

Summary of Contents for FXSQ100M7V1B

Page 1: ...INSTALLATION AND OPERATION MANUAL FXSQ20M7V1B FXSQ25M7V1B FXSQ32M7V1B FXSQ40M7V1B FXSQ50M7V1B FXSQ63M7V1B FXSQ80M7V1B FXSQ100M7V1B FXSQ125M7V1B System air conditioner ...

Page 2: ...2 2 5 6 7 4 3 4 4 1 3 2 4 5 5 5 2 1 2 3 6a 6a 2 3 1 4 680 85 6b 6b 1 3 2 4 6 5 50 200 45 680 6c 6c 1 5 2 3 7 4 680 65 3 3 1 4 3 4 2 800 630 B A 145 7c 7c 4 2 2 3 1 460 180 350 A 8 8 1 1 5m 0 625mm 2 6 1 5 4 A 3 9 9 1 100mm 7a 7a 1 3 2 2 1 3 10 10 3 2 1 6 5 4 ...

Page 3: ... 4 2 1 13 13 2 2 1 14 14 L N IN D OUT D F1 F2 F1 F2 Control box LN P1 P2 P1 P2 F1 F2 T1 T2 LN P1 P2 F1 F2 T1 T2 LN P1 P2 F1 F2 T1 T2 LN P1 P2 F1 F2 T1 T2 P1 P2 P1 P2 2 4 5 3 1 16 16 IN D OUT D F1 F2 F1 F2 Control box IN D OUT D F1 F2 F1 F2 Control box L N P1 P2 LN P1 P2 F1 F2 T1 T2 1 3 6 2 20 20 S M S S M 1 2 3 19 19 1 2 5 6 3 4 7 8 9 15 15 21 21 SETTING 2 1 4 3 11c 11c 5 4 1 3 2 18 18 F2 T1 T2 FO...

Page 4: ...r följande standard er eller andra normgivande dokument under förutsättning att användning sker i överensstämmelse med våra instruktioner respektive utstyr er i overensstemmelse med følgende standard er eller andre normgivende dokument er under forutssetning av at disse brukes i henhold til våre instrukser vastaavat seuraavien standardien ja muiden ohjeellisten dokumenttien vaatimuksia edellyttäen...

Page 5: ...er pattern for installation Do not install accessories on the casing directly Drilling holes in the casing may damage electrical wires and consequently cause fire Accessories Check if the following accessories are included with your unit Screws for fixing panels are attached to the air inlet panel Optional accessories There are two types of remote controllers wired and wireless Select a remote contr...

Page 6: ...choose one of the possibilities as listed further Standard rear suction See figure 6a Installation with rear duct and duct service opening See figure 6b Installation with rear duct no duct service opening See figure 6c Tick when checked Is the indoor unit fixed firmly The unit may drop vibrate or make noise Is the gas leak test finished It may result in insufficient cooling Is the unit fully insulated Co...

Page 7: ...13 3 Tighten the upper nut 4 Fix the paper pattern for installation The paper pattern for installation corresponds with the measurements of the ceiling opening Consult the builder for details Attach the paper pattern for installation to the unit with the attached screws as shown in figure 17 The paper pattern for installation is marked for 3 types of ceiling openings Read the notations carefully wh...

Page 8: ...nd insulate them Connect the drain hose to the drain pipe on the indoor unit and tighten it with the metal clamp To ensure a downward slope of 1 100 install hanging bars every 1 to 1 5 m If unifying multiple drain pipes install the pipes as shown in figure 9 2 After piping work is finished check if drainage flows smoothly Open the water inlet lid add approximately 1 l of water gradually and check the...

Page 9: ...hed the system may cause a malfunction Electrical characteristics MCA Min circuit Amps A MFA Max Fuse Amps A KW Fan Motor Rated Output kW FLA Full Load Amps A Specifications for field supplied fuses and wire Allowable length of transmission wiring between indoor and outdoor units and between the indoor unit and the remote controller is as follows 1 Outdoor unit indoor unit max 1000 m total wiring le...

Page 10: ...er to the Installation manual of the remote controller supplied with the remote controller 6 Never connect the power supply wiring to the terminal board for transmission wiring This mistake could damage the entire system 7 Use only specified wires and tightly connect wires to the terminals Be careful that wires do not place external stress on the terminals Keep wiring in neat order so that they do ...

Page 11: ...hen set the first code No to 1 Then set second code position No to 01 for forced off and to 02 for on off operation forced off at factory set See figure 21 Centralized control For centralized control it is necessary to designate the group No For details refer to the manual of each optional controller for centralized control INSTALLATION OF THE DECORATION PANEL Refer to the installation manual attach...

Page 12: ...he shade 4 Fix the air filter Align the two hanger brackets and push the two clips in their place pull the cloth if necessary Confirm that four hangers are fixed 5 Shut the air inlet grille Only for bottom suction Refer to item no 1 6 After turning on the power press FILTER SIGN RESET button The TIME TO CLEAN AIR FILTER display is turned off Caution Only a qualified service person is allowed to perfor...

Page 13: ... the unit turn on the main power switch at least 6 hours before operation What to do when stopping the system for a long period Turn on FAN OPERATION for half a day and dry the unit Refer to the operation manual of the outdoor unit Cut off the power supply When the main power switch is turned on some wattage is being consumed even if the system is not operating The remote controller display is tur...

Page 14: ...H ADAPTOR FOR WIRING RyC RyF MAGNETIC RELAY RyH MAGNETIC RELAY J1EH F1U F2U FUSE 250 V 5 A X1A X2A CONNECTOR WIRING ADAPTOR X1M TERMINAL STRIP CONNECTOR FOR OPTIONAL PARTS X16A CONNECTOR WIRING ADAPTOR X18A CONNECTOR WIRING ADAPTOR FOR ELECTRICAL APPENDICES FIELD WIRING BLK BLACK TERMINAL BLU BLUE CONNECTOR ORG ORANGE WIRE CLAMP PNK PINK PROTECTIVE EARTH SCREW RED RED WHT WHITE YLW YELLOW RECEIVER...

Page 15: ...NOTES NOTES ...

Page 16: ...Zandvoordestraat 300 B 8400 Oostende Belgium 4PWEN15110 1 ...

Reviews: