CAUTION

• Be sure to attach the sealing material or putty (field supplied) 

to hole of wiring to prevent the infiltration of water as well as 
any insects and other small creatures from outside. Other-
wise a short-circuit may occur inside the electric parts box.

• When clamping the wires, be sure no pressure is applied to 

the wire connections by using the included clamping material 
to make appropriate clamps. Also, when wiring, make sure 
the lid on the electric parts box fits snugly by arranging the 
wires neatly and attaching the electric parts box lid firmly. 
When attaching the electric parts box lid, make sure no wires 
get caught in the edges. Pass wiring through the wiring 
through holes to prevent damage to them.

• Make sure the remote controller wiring, the wiring between 

the units, and other electrical wiring do not pass through the 
same locations outside of the unit, separating them by at 
least 50mm, otherwise electrical noise (external static) could 
cause mistaken operation or breakage.

CAUTION FOR WIRING

• For connection to the terminal block, use ring type crimp style 

terminals with insulation sleeve or insulate the wirings properly. 

• Connect the terminal as shown in Fig. 29.
• Do not carry out soldering finish when stranded wires are 

used. (Otherwise, the loosening of wires may result in abnor-
mal heat radiation.)

(Abnormal heating may occur if the wirings are not tightened 
securely.)

• Use the required wirings, connect them securely and fix 

these wirings securely so that external force may not apply to 
the terminals.

• Use a proper screw driver for tightening the terminal screws.

If an improper screw driver is used, it may damage the screw 
head and a proper tightening cannot be carried out.

• If a terminal is over tightened, it may be damaged.

Refer to the table shown below for tightening torque of terminals.

Table 3   

• Do not carry out soldering finish when stranded wirings are 

used.

WARNING

• When wiring, form the wirings orderly so that the control box 

lid can be securely fastened. If the control box lid is not in 
place, the wirings may come out or be sandwiched by the 
box and the lid and cause electric shocks or a fire.

9-2

WIRING EXAMPLE 

• Fit the power supply wiring of each unit with a switch and 

fuse as shown in the drawing. 

COMPLETE SYSTEM EXAMPLE (3 systems) 

1.

When using 1 remote controller for 1 indoor unit. (Nor-
mal operation)

2.

For group control or use with 2 remote controllers

Tightening torque (N·m)

Terminal block for remote controller and 
transmission wirings

0.88 ± 0.08

Terminal for power supply

1.47 ± 0.14

Earth terminal

1.69 ± 0.25

Insulation sleeve

Ring type crimp 
style terminal

Wiring

Fig. 28

Fig. 29

      

       

    

Power supply wiring

Transmission wiring

Switch

Fuse

Power supply

Main
switch

Remote controller

Indoor unit

BS unit
(Only for Heat
recovery 
system)

L N

IN/D

OUT/D

F1 F2 F1 F2

Control box

L N

P

1

P

2

P

1

P

2

F

1

F

2

T

1

T

2

P

1

P

2

P

1

P

2

F

1

F

2

T

1

T

2

L N

P

1

P

2

P

1

P

2

F

1

F

2

T

1

T

2

L N

L N

P

1

P

2

P

1

P

2

F

1

F

2

T

1

T

2

Outdoor unit

No. 1
System

Indoor 
unit A

Indoor 
unit B

Indoor 
unit C

Most
downstream
Indoor unit 

Power supply

220-240V

50Hz

or

220V

60Hz

IN/D

OUT/D

F

1

F

2

F

1

F

2

Control box

L N

P

1

P

2

P

1

P

2

F

1

F

2

T

1

T

2

L N

P

1

P

2

F

1

F

2

T

1

T

2

L N

P

1

P

2

F

1

F

2

T

1

T

2

L N

P

1

P

2

F

1

F

2

T

1

T

2

P

1

P

2

P

1

P

2

L N

Outdoor unit

No. 2
System

Indoor unit A

Indoor unit B

Indoor unit C

Most 
downstream
indoor unit

For use with 2
remote controllers

Power supply

220-240V

50Hz

or

220V

60Hz

Fig. 30

01_EN_3P172532-7B.fm  Page 10  Wednesday, October 14, 2015  6:17 PM

Summary of Contents for FXHQ100MAVE

Page 1: ...ES DE LA INSTALACI N CONSERVE ESTE MANUAL PARA POSIBLES CONSULTAS FUTURAS PRIMA DELL INSTALLAZIONE LEGGERE ATTENTAMENTE LE PRESENTI ISTRUZIONI CONSERVARE IL PRESENTE MANUALE IN UN LUOGO FACILMENTE ACC...

Page 2: ...0MVE FXSQ25MVE FXSQ32MVE FXSQ40MVE FXSQ50MVE FXSQ63MVE FXSQ80MVE FXSQ100MVE FXSQ125MVE FXKQ25MVE FXKQ32MVE FXKQ40MVE FXKQ63MVE FXAQ20MVE FXAQ25MVE FXAQ32MVE FXAQ40MVE FXAQ50MVE FXAQ63MVE FXUQ71MV1 FXU...

Page 3: ...a foundation that can withstand its mass Insufficient strength may result in the air conditioner falling down and causing injury In addition it may lead to vibration of indoor units and cause unpleas...

Page 4: ...the paper pattern For the installation of an outdoor unit refer to the installation manual attached to the outdoor unit Do not install or operate the unit in rooms mentioned below Laden with mineral o...

Page 5: ...alled on ceilings up to 3 5 m in height However if the ceiling is higher than 2 7m the remote control will have to be set locally Refer to 11 FIELD SETTING on page 12 3 Use suspension bolts for instal...

Page 6: ...e suction grille opened Holding the knob on the back of suction grille pull to the front direction to remove Refer to Fig 4 2 Detach the dressing boards left and right Remove the side panel fixing scr...

Page 7: ...is tilted to the left or to the left and back Place it level or tilt it slightly to the left or the back Within 1 CAUTION Setting the unit at an angle opposite to the drain piping might cause leaks 6...

Page 8: ...indoor unit The refrigerant is pre charged in the outdoor unit When connecting the pipings to the air conditioner make sure to use a spanner and a torque wrench as shown in Fig 16 For the dimension of...

Page 9: ...t piping Once this is done con nect the indoor unit with a flared or a flanged connection Nitrogen should be set to 0 02 MPa with a pressure reducing valve if brazing while inserting nitrogen into the...

Page 10: ...according to the procedure shown below Select converging drain pipes whose gauge is suitable for the operating capacity of the unit 2 Confirm that smooth drainage is achieved after the pip ing work A...

Page 11: ...WIRINGS Method of wiring power supply units and connecting remote controller wiring Refer to Fig 26 Power supply wiring Hold the electric parts box lid and loosen the anchoring screws 2 pc then remove...

Page 12: ...is used it may damage the screw head and a proper tightening cannot be carried out If a terminal is over tightened it may be damaged Refer to the table shown below for tightening torque of terminals...

Page 13: ...r to Fig 30 and 8 3 9 4 FOR REMOTE CONTROL FORCED OFF AND ON OFF OPERATION 1 Wire specifications and how to perform wiring Connect input from outside to terminals T1 and T2 of the terminal block for r...

Page 14: ...in the field set mode select mode No 12 then set the first code switch No to 1 Then set second code position No to 01 for FORCED OFF and 02 for ON OFF OPERATION FORCED OFF at factory set 12 TEST OPER...

Page 15: ...1511 HT 3P172532 7B EM02A086D 00_CV_3P172532 7B fm Page 2 Monday August 31 2015 5 20 PM...

Reviews: